PRTxxMF series readers Operating Manual.doc
2019-01-29
9/54
4.1.1.
Wiegand Formats
When using
Wiegand
transmission format, data is send
to the host using sequences of short pulses transmitted
over CLK and DTA lines. Depending on the selected
version of the transmission format, the reader can send
26, 32, 34, 42 or 66 bits to the host. PIN can be
transmitted as a whole (when # key is pressed ) or each
digit separately – see section 7.
In
Wiegand
format all LED indicators and buzzer of the
reader can be controlled by IN1 and IN2 inputs. Both
inputs (IN1 and IN2) are triggered by shorting them to
supply minus. Input functions can be configured within
Memory Reset procedure or with RARC software. In
addition, whenever card is read or PIN is entered reader
activates momentary LED SYSTEM and buzzer.
Wiegand transmission is unidirectional and data is sent to
host device without receipt confirmation.
Note: For card codes which require more bits than the number of bits available in the selected data
transmission format, reader omits the most significant bits (MSB-s) of the card code. As a result
transmission from a reader is not equal to the full card code.
4.1.2.
Magstripe Formats
When using
Magstripe
transmission format, data is
transmitted to the host via CLK and DTA lines. In
Magstripe
format all LED indicators and buzzer of the
reader can be controlled by IN1 and IN2 inputs. Both
inputs (IN1 and IN2) are triggered by shorting them to
supply minus. Input functions can be configured within
Memory Reset procedure or with RARC software. In
addition, whenever card is read or PIN is entered reader
activates momentary LED SYSTEM and buzzer.
Card code is always transmitted as a whole number (no
digits are lost) while PIN can be transmitted as a whole
(when # key is pressed ) or each digit separately – see
section 7.
4.1.3.
RACS Format
When using
RACS
format, the PRTxxMF reader
communicates with the access controller via CLK/DTA
lines. Unlike in the Wiegand
and
Magstripe
formats, the
PRTxxMF unit using
RACS
format requires an individual
address (ID=0…3) to be set during configuration of
reader’s operating mode (Memory Reset procedure or
RARC software). In
RACS
format, communications
between the PRTxxMF reader and the host is bidirectional
which allows the controller to monitor the communication.
The reader’s LED-s and the buzzer are controlled by the
host unit. When all LED-s are flashing it indicates that
reader lost communication with the host unit.
When in
RACS
mode triggering of the IN1 disables
reading of the card and keypad. This input can be used
for temporary disabling of the reader. The IN2 is not used
in
RACS
mode. PIN is transmitted as a whole when # key
is pressed.
Summary of Contents for PRT MF Series
Page 47: ...PRTxxMF series readers Operating Manual doc 2019 01 29 47 54 ...
Page 48: ...PRTxxMF series readers Operating Manual doc 2019 01 29 48 54 ...
Page 49: ...PRTxxMF series readers Operating Manual doc 2019 01 29 49 54 ...
Page 50: ...PRTxxMF series readers Operating Manual doc 2019 01 29 50 54 ...
Page 51: ...PRTxxMF series readers Operating Manual doc 2019 01 29 51 54 ...
Page 52: ...PRTxxMF series readers Operating Manual doc 2019 01 29 52 54 ...
Page 53: ...PRTxxMF series readers Operating Manual doc 2019 01 29 53 54 ...