Roger Access Control System 

Installation guide for                                   

PR411DR/PR411DR-BRD Access Controllers 

Firmware version: 1.18.6 or newer 

Hardware version: 1.4 

 

Document version: Rev. K 

 

 

 

 
 

 

 

 

 

 
 

© 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document is subject to the Terms of Use in their current version published at 

the 

www.roger.pl

 website of the Roger sp. z o.o. sp.k. company (hereinafter referred to as ROGER). 

Summary of Contents for PR411DR

Page 1: ...ware version 1 18 6 or newer Hardware version 1 4 Document version Rev K 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at...

Page 2: ...door lock 10 3 5 Communication with controller 11 3 6 Communication of controller with peripheral devices 11 3 6 1 PRT readers and XM 2 expander 11 3 6 2 PRT and third party readers Wiegand 12 3 7 Inp...

Page 3: ...ader s operating in RACS CLK DTA PRT series terminals or Wiegand 26 66bit format Controllers can be configured with PR Master software installed on computer and they can be connected to computer by me...

Page 4: ...for controller IN7 IN7 input line BAT Backup battery GND Ground BAT Backup battery IN6 IN6 input line IO1 IO1 output line IN5 IN5 input line IO2 IO2 output line GND Ground IN1 IN1 input line B RS485 c...

Page 5: ...ly for controller IO1 IO1 output line COM REL1 relay common terminal IO2 IO2 output line NC REL1 relay output NC IN1 IN1 input line NO REL1 relay output NO IN2 IN2 input line CLK RACS CLK DTA comm bus...

Page 6: ...PR411DR Installation Guide Rev K doc 2016 10 28 6 17 Fig 3 Typical connection diagram for PR411DR controller...

Page 7: ...RMED DISARMED Current arming mode OPEN Door unlocked SYSTEM Various signalling functions LINK Data transmission by means of RS485 bus Fig 4 PR411DR front panel 3 2 2 PR411DR BRD controller According t...

Page 8: ...owers supply shortage If the voltage at backup battery drops below approx 10V then the battery is automatically disconnected from controller and remains disconnected until mains power supply returns D...

Page 9: ...PR411DR Installation Guide Rev K doc 2016 10 28 9 17 Fig 6 PR411DR controllers supplied with 18VAC Fig 7 PR411DR controllers supplied with 24VDC...

Page 10: ...be ensured on power supply unit side Controllers can be supplied from single power supply unit if the output power is sufficient 3 4 Connection of door lock In majority of cases door locking devices...

Page 11: ...ystem guarantees proper communication in a distance of up to 1200 meters as well as high resistance to interferences 3 6 Communication of controller with peripheral devices The communication of contro...

Page 12: ...sers can authorize alternatively on PRT or Wiegand reader In case of Wiegand Magstripe readers it is necessary to select adequate data format otherwise controller will not recognize transmissions from...

Page 13: ...supply switched off All devices connected to the same communication bus RS485 and RACS CLK DTA should be connected to the same negative potential GND In order to satisfy this requirement connect the p...

Page 14: ...onfigured controller must be restarted via RESET button or powering device off and on to make new settings valid The address range is 00 127 and if the address is in range 100 127 then the controller...

Page 15: ...programming of new MASTER card This procedure requires connection of any PRT series reader Remove connections to CLK and DTA terminals Connect CLK with DTA Restart the controller press RESET button o...

Page 16: ...required to place FDM jumper in order to put the device in firmware download mode Therefore firmware update can be performed by means of RS485 bus of access control system Firmware update procedure P...

Page 17: ...n REL2 galvanic separation and battery assembly This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact o...