Installation guide for  

PR302 v2.1 

Rev. G 

Summary of Contents for PR302

Page 1: ...rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER Installation guide for PR302 v2 1 Rev G ...

Page 2: ...ess ID number 00 99 The controller s address can be set manually using Memory Reset procedure or from PC computer In order to set change controller s address from PC connect it to any free COM port and then using PR Master program enrol it to database Once the unit is found by PR Master use relevant command to change its address and then disconnect it from PC and connect to designated access insta...

Page 3: ... high impedance when active triggered state outputs short to supply minus GND Each output can switch max 1A DC while voltage connected to it must not exceed 15VDC The IO1 and IO2 have internal over current protection which switches them off for currents above 1A RS485 Communication bus The communications bus consist of three lines A B and cable s shield SHLD Electrically it represents RS485 standa...

Page 4: ...ny other device connected to CLK DTA line is limited to 150m nevertheless when using RACS interface communication will run satisfactory for up to 500m distances however it is not guaranteed in every case For best card reading results controller should be installed on non metal surface When installed on metal structure the reading range can be reduced up to 50 This effect can be reduced by placing ...

Page 5: ...han 2 18 6 Simplified Memory Reset restores default settings and enables programming of new MASTER card while controller address is automatically configured as ID 00 Press and hold MEMORY RESET button until LED OPEN green pulsates Release MEMORY RESET button Read any card at the controller this will be a new MASTER card After a few seconds the controller shall restart automatically and switch to n...

Page 6: ... new firmware is programmed into the controller by means of communication bus and doesn t require de installation of the unit from its original location For firmware upgrade the RogerISP program is required Once the controller is upgraded it should be fully reconfigured also it is necessary to update the RACS database which must be aligned with current version of controller s firmware command Netw...

Page 7: ... not clean with alcohols solvents petrol disinfectants acids rust removers etc Damages resulting from improper maintenance and usage are not covered by manufacturer warranty Ordering information PR302 Indoor access controller with built in EM 125 kHz proximity reader and keypad XM 2 Input output addressable extension module with plastic enclosure digital communication according to RACS Clock and D...

Page 8: ...PR302 Installation Guide 2020 10 19 8 10 ...

Page 9: ...PR302 Installation Guide 2020 10 19 9 10 ...

Page 10: ...ctric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the document Contact Roger sp z o o sp k 82 400 Sztum Gościszewo 59...