Roger Access Control System 

Installation guide for                                   

PR102DR/PR102DR-BRD Access Controllers 

Firmware version: 1.18.6 or newer 

Hardware version: 1.0 

 

Document version: Rev. E 

 

 

 

 
 

 
 

 
 

 
 

 

 
 

 
 
 

© 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document is subject to the Terms of Use in their current version published at 

the 

www.roger.pl

 website of the Roger sp. z o.o. sp.k. company (hereinafter referred to as ROGER). 

Summary of Contents for PR102DR

Page 1: ...mware version 1 18 6 or newer Hardware version 1 0 Document version Rev E 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER ...

Page 2: ...3 7 1 Inputs 8 3 7 2 Relay output 8 3 7 3 General purpose output 8 3 8 Installation guidelines 8 4 Configuration 9 4 1 Controller address 9 4 1 1 Addressing by means of jumpers 9 4 1 2 Addressing during firmware update Fixed ID 10 4 1 3 Addressing during Memory Reset procedure 10 4 1 4 Addressing by means of PR Master software 10 4 2 Memory Reset procedure 10 4 2 1 Simplified Memory Reset Procedur...

Page 3: ...r connection of external reader PR102DR controllers are not equipped with built in reader and they require connection of external reader s operating in RACS CLK DTA PRT series terminals Controllers can be configured with PR Master software installed on computer and they can be connected to computer by means of communication interface e g UT 2USB UT 4DR RUD 1 or by means of CPR32 NET network contro...

Page 4: ...s Table 2 PR102DR terminals Terminal Description Terminal Description DTA RACS CLK DTA comm bus IN1 IN1 input line CLK RACS CLK DTA comm bus GND Ground B RS485 communication bus 12V 12VDC power supply A RS485 communication bus NO REL1 relay output NO OUT1 OUT1 output line COM REL1 relay common terminal IN2 IN2 input line NC REL1 relay output NC ...

Page 5: ...PR102DR Installation Guide Rev E doc 2017 09 18 5 13 Fig 2 PR102DR connection diagram ...

Page 6: ...re and during firmware update procedure Table 3 PR102DR front panel DC DC supply ARMED DISARMED Current arming mode OPEN Door unlocked SYSTEM Various signalling functions LINK Data transmission on RS485 bus Fig 3 PR102DR front panel 3 2 2 PR102DR BRD controller According to fig 4 PR102DR BRD is equipped with 4 LED indicators and RST button on its PCB The button can be used to restart the controlle...

Page 7: ...age surge can occur when current flow is interrupted and it can interfere with the controller electronic components In extreme cases it may result in improper operation of the controller or even freeze Moreover overvoltage condition causes quicker wear of relay contacts In order to limit this adverse effect it is necessary to use a general type semiconductor diode e g 1N4007 one piece of such diod...

Page 8: ...d output lines Functions are assigned to inputs and outputs by means of PR Master software Default function for REL1 relay output is door unlocking 3 7 1 Inputs All inputs IN1 IN2 of controllers have identical electric structure and can be configured as NO or NC lines using PR Master software The NO input is triggered by shorting it to supply minus GND while the NC input must be normally shorted t...

Page 9: ... ID number from range 00 99 Two or more devices with the same address result in communication conflict and make a proper communication with these devices impossible Following addressing methods are available By means of jumpers During update of controller firmware by means of Roger ISP software so called Fixed ID Manually during Memory Reset procedure By means of PR Master software The first two m...

Page 10: ...an be configured during Memory Reset procedure see 4 2 Memory Reset procedure Note Software address is effective only if the address set with jumpers on the controller is in range of 100 127 and FixedID is None 4 1 4 Addressing by means of PR Master software Software address can be configured by means of PR Master software In such case connect the controller to PC via communication interface e g U...

Page 11: ...e requires connection of PRT series reader with keypad e g PRT12LT Remove connections to CLK and DTA terminals Connect CLK with DTA Restart the controller press RESET button or switch power supply off on LED OPEN shall start to pulsate Disconnect CLK and DTA Connect PRT series reader with keypad e g PRT12LT to CLK and DTA lines without switching power supply off and take further steps by means of ...

Page 12: ...RST pins or switch power off on In Firmware window select firmware hex file can be downloaded from www roger pl and then select the button Program After firmware upload remove jumper from FDM pins and reset device press RESET button or switch power off on Note If the controller is not responding and LED SYSTEM orange is on after firmware update then it is necessary to reset see 4 2 Memory Reset pr...

Page 13: ...user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is s...

Reviews: