background image

 

 

                                                                                         

                                                                                           

                                                                                           

 

RODIX INCORPORATED 

2316 23

rd

 Ave., ROCKFORD IL 61104 

TOLL FREE (800) 562-1868, FAX (815) 316-4701 

E-mail [email protected] 

www.rodix.com 

 

FEEDER CUBE

 

CE-48 

Plus

 

 ALL PURPOSE 

OIL RESISTANT MODEL 
IMPORTANT: APPLICATION NOTE 

 

Replacement Parts:

 

 

Item 
Designation Quantity Characteristics Rodix P/N  

Manufacturer 

P/N 

Control Card   (quan. 1) 

240V   

Rodix No. 123-294* 

Fuse   

(quan. 1) 

8 A, 250V 

Rodix No. 106-20* 

Littelfuse 0214008 

Fuse Holder    (quan. 1) 

20 A, 250V  Rodix No. 106-17 

Littelfuse 03540901ZXGY 

Triac 

 (quan. 

1) 

  Rodix 

No. 

115-32* 

ST 

Micro. 

BTA40-600B-LF 

S1 

 

(quan. 1) 

DPST   

Rodix No. 104-80* 

Tyco 1520284-1 

Switch Boot  (quan. 1) 

 

 

Rodix No. 104-26 

APM Hex.  C1131/35-20 

Pot. Assembly (quan. 1) 

100K ohm 

Rodix No. 123-229   

Terminals  

 

 

20A, 600V,2C Rodix No. 105-90 

Altech CSCP2.5T 

Knob 

 

     Rodix 

No. 

122-10 

APEM 

42011-3B-1/4 

 

*Recommended spare parts to keep in stock. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                                     CE-48 Plus 24-211.doc 9/6/2012 Cover

 

                                    

Summary of Contents for 121-500-0750

Page 1: ...1 240V Rodix No 123 294 Fuse quan 1 8 A 250V Rodix No 106 20 Littelfuse 0214008 Fuse Holder quan 1 20 A 250V Rodix No 106 17 Littelfuse03540901ZXGY Triac quan 1 Rodix No 115 32 STMicro BTA40 600B LF...

Page 2: ...must be provided by the user A power plug socket combination can be utilized for this purpose The plug and socket must have a breaking capacity of at least the amperage of the vibratory feeder s 2006...

Page 3: ...ONTROL A Run Jumper has been installed at the factory as shown on the enclosed wiring diagram Remote OFF ON operation of the CE 40 Plus Series Feeder Cube control can be configured to operate in one o...

Page 4: ...ns and fax any needed information To return a control for IN or OUT of warranty service please ship it prepaid to Rodix Inc ATTN Repair Department If under warranty Rodix will repair or replace your c...

Page 5: ...l 14 AWG Lt Bu 14 AWG Bl 14 AWG 240 VAC Gr Yl 14 AWG Bl 11 4 50 60 Hz Gn Yl COM HOT 20VK1 1 2 LINE FILTER Lt Bu PE Customer Supplied Disconnect Device PE 2 1 13 10 8 EU WIRING 11 INPUT INTERLOCK 6 8 8...

Page 6: ...ns for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drai...

Page 7: ...performed by Rodix at L F Research 12790 Route 76 Poplar Grove IL 61065 Machine Description Vibratory Feeder Control Makes CE 41 Plus CE 41H Plus CE 43 Plus CE 43H Plus CE 48 CE 48 Plus CE 48H Plus C...

Page 8: ...he standard 1 When the standard does apply When a 230V machine is not powered by a step down transformer there should not be a problem meeting this standard if all the vibratory feeders on one machine...

Page 9: ...down transformer that is installed in a factory Thus the machine is powered by a higher voltage distribution system that is not directly connected to the 230V public low voltage system Because of thi...

Page 10: ...ether if they always start and stop at the same time Actual testing may prove that the number of On Off cycles shown in the chart can nearly be doubled when the Soft Start pot is adjusted for a one se...

Reviews: