File No. E183233
RODIX INCORPORATED
TOLL FREE (800) 562-1868, FAX (815) 316-4701
E-mail [email protected]
rodix.com
FEEDER CUBE ®
VF-3-OF, P/N 121-000-0777* and 121-200-0777
* Includes CFR vibration sensor P/N 123-215
OPEN FRAME MODEL
IMPORTANT: APPLICATION NOTE
Input: 85 - 264 VAC, 50/60 HZ.
Single Unit Fuse Size: 5 AMPS
Output: 0 - 120/240 VAC
Maximum output voltage matches input voltage
Output Frequency: 5 - 180Hz
Rated Output Current: 3 Amps at 120V or 2 Amps at 240V
Model Information: The Autotune Series of Variable Frequency Feeder Cubes® generates an output frequency for feeding
that is independent from the power line frequency. An optional vibration sensor, P/N 123-215, can be used to maintain the
vibratory feeder at a constant feed rate. The start/stop operation of the output can be controlled with an optional parts
sensor. For more information on this control, refer to the enclosed Adjustments and Set Up pages.
Mount Open Frame controls within an enclosure. Mount the fuse holders external to the control with #8 screws. For single
phase 120 or 240 VAC installations, install a “Hot” wire fuse, don’t fuse the neutral wire. Use only the Littlefuse 3AB “Fast
Acting” type of fuse. The customer supplied power switch wires to the fuse(s). Disconnect the power before making
electrical connections to the terminal block plugs. The customer supplied power switch should be rated 10 amps, 240V or
more.