FEEDER CUBE ® 

 

 

VF-12, P/N 121-000-0755* and 121-200-0755 

 

 

* Includes CFR vibration sensor P/N 123-215 

 

 

GENERAL PURPOSE MODEL 

 

 

IMPORTANT:  APPLICATION NOTE   

 

 

 

  

              

 

 

  

Input: 85 - 264 VAC, 50/60 HZ. 
Single Unit Fuse Size: 10 AMPS 
Output: 0 - 120/240 VAC 
Maximum output voltage matches input voltage 

 

 

Output Frequency: 5 - 180Hz 

 

 

Rated Output Current:  12 Amps at 120V or 9 Amps at 240V 

 

 
 

 

Model Information:  The Autotune Series of Variable Frequency Feeder Cubes® generates an output frequency for feeding 
that is independent from the power line frequency.  An optional vibration sensor, P/N 123-215, can be used to maintain the 
vibratory feeder at a constant feed rate.  The start/stop operation of the output can be controlled with an optional parts 
sensor.  For more information on this control, refer to the enclosed Adjustments and Set Up pages. 

 
 

 

 
 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

© 2005, 2020 RODIX 

INC

 

 

 

 

 

VF-12 E cover.docx 2/12/21  Page 1

Summary of Contents for 121-000-0755

Page 1: ...put Frequency 5 180Hz Rated Output Current 12 Amps at 120V or 9 Amps at 240V Model Information The Autotune Series of Variable Frequency Feeder Cubes generates an output frequency for feeding that is...

Page 2: ...RODIX INC Toll Free 800 562 1868 FAX 815 316 4701 Email custserve rodix com rodix com VF 12 E cover docx 8 21 20 Page 2 RODIX INC FEEDER CUBE VF Series WIRING DIAGRAM Figure 1...

Page 3: ...ngs 2 Enter Restores User Settings 2 Restore Settings 3 Enter Restores User Settings 3 Save Settings 1 Enter Saves User Settings 1 Save Settings 2 Enter Saves User Settings 2 Save Settings 3 Enter Sav...

Page 4: ...single phase 120 or 240 VAC installations to bypass the phase 2 fuse L2 To bypass remove the wire connecting TB1 L2 to the L2 fuse holder Remove the terminal end of the wire connecting the L2 fuse to...

Page 5: ...r setting is displayed in the following manner A 50 0 8 Limiting the Maximum Output of Control The Max Amplitude setting can be adjusted to keep a vibratory feeder from hammering or vibrating excessiv...

Page 6: ...arts load fluctuations adjust the frequency down by 2 or 3Hz so that the feeder becomes slightly over tuned B Auto Scan scans to locate the bowl s resonate frequency Once auto tracking has found the r...

Page 7: ...to a known setting Once a feed system has been set up properly the setting should be manually saved into the Save Settings1 memory If an operator disturbs the settings the Restore Settings1 feature ca...

Page 8: ...ettings 2 Restore Settings 3 Enter Restores User Settings 3 Save Settings 1 Enter Saves User Settings 1 Save Settings 2 Enter Saves User Settings 2 Save Settings 3 Enter Saves User Settings 3 Factory...

Page 9: ...ies Control 1 Add a wire from term TB2 1 of the VF master control to TB2 11 of the subordinate control 2 Add a wire from TB2 2 of the VF master control to TB2 12 of the subordinate control 3 Move the...

Page 10: ...f a nearby noise source Solutions for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock inpu...