No. Parameter Name & Description
Values
Re
la
te
d
UTILITY (F
ile E)
Dri
ve . .
.
198
[Load Frm Usr Set]
Loads a previously saved set of
parameter values from a selected user
set location in drive nonvolatile memory
to active drive memory.
Default:
Options:
0
0
1
2
3
“Ready”
“Ready”
“User Set 1”
“User Set 2”
“User Set 3”
Di
agnost
ic
s
216
[Dig In Status]
Status of the digital
inputs.
MO
T
O
R . .
.
To
rq
.
. .
059
[SV Boost Filter]
Sets the amount of filtering used to boost
voltage during Sensorless Vector
operation.
Default:
Min/Max:
Units:
500
0/32767
1
0
0
0
0
0
0
x
x
0
0
0
0
0
0
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
= Input Present
0
= Input Not Present
x = Reserved
Bit #
Digital In1
Digital In2
Digital In3
Digital In4
Digital In5
Digital In6
In1 DLogRslt
(1)
In2 DLogRslt
(1)
In3 DLogRslt
(1)
In4 DLogRslt
(1)
In5 DLogRslt
(1)
In6 DLogRslt
(1)
Nibble 1
Nibble 2
Nibble 3
Nibble 4
(1)
Enhanced firmware 2.001 & later.
E C
➊ ➌
➋
➏
➎
➍
No.
Description
➊
File
– Lists the major parameter file category.
➋
Group
– Lists the parameter group within a file.
➌
No.
– Parameter number.
=
Parameter value can not be changed until drive is stopped.
= 32 bit parameter.
= 32 bit parameter in Enhanced Control drives only.
= Parameter only displayed when [Motor Cntl Sel] is set to “4.”
➍
Parameter Name & Description
– Parameter name as it appears on an LCD HIM, with a brief
description of the parameters function.
= This parameter is specific to Standard Control drives.
= This parameter will only be available with Enhanced Control drives.
➎
Values
– Defines the various operating characteristics of the parameter. Three types exist.
ENUM
Default:
Options:
Lists the value assigned at the factory. “Read Only” = no default.
Displays the programming selections available.
Bit
Bit #:
Lists the bit place holder and definition for each bit.
Numeric Default:
Min/Max:
Units:
Lists the value assigned at the factory. “Read Only” = no default.
The range (lowest and highest setting) possible for the parameter.
Unit of measure and resolution as shown on the LCD HIM.
Important:
Some parameters will have two unit values:
•
Analog inputs can be set for current or voltage with 320 [Anlg In Config].
•
Values that pertain to Enhanced Control drives only will be indicated by “
.
”
Important:
When sending values through DPI ports, simply remove the decimal
point to arrive at the correct value (i.e. to send “5.00 Hz,” use “500”).
➏
Related
– Lists parameters (if any) that interact with the selected parameter. The symbol “
”
indicates that additional parameter information is available in Appendix C.
32
32
E C
FV
Standard
E C
E C
Summary of Contents for PowerFlex 70
Page 4: ...soc 2 Notes ...
Page 134: ...A 18 Supplemental Drive Information Notes ...
Page 168: ...Index 14 ...
Page 169: ......