Run Multi-mode Express Setup in Short Press Mode
Be aware of the following conditions that cause the switch to exit Short Press
mode.
To run multi-mode Express Setup in Short Press mode, follow these steps.
1. Apply power to the switch.
When the switch powers on, it begins its power-on sequence. The
power-on sequence can take as many as 90 seconds to complete.
2. Make sure that the power-on sequence has completed by verifying that
the EIP Mod and Setup status indicators are flashing green.
If the switch fails the power-on sequence, the EIP Mod status indicator
turns red.
If you do not press the Express Setup button within 5 minutes after the
power-on sequence is complete, the Setup status indicator turns off.
However, you can still run Express Setup after the Setup status indicator
turns off.
3. Press and hold the Express Setup button until the Setup status indicator
flashes green during seconds 1…4, and then release.
The switch selects a port to use for Express Setup.
Condition
Status Indicator Behavior
A non-default configuration exists on the switch.
The Setup status indicator turns red for 10 seconds.
You do not connect to the Express Setup port within 2
minutes from when the port status indicator flashes
green.
The unconnected port status indicator and the Setup
status indicator turn off.
No DHCP request is received for 2 minutes from when
you connect to the Express Setup port.
The Setup status indicator turns red for 10 seconds.
No browser session is started for 2 minutes after an IP
address is assigned to the computer.
The unconnected port status indicator and the Setup
status indicator turn off.
You disconnect your computer from the switch before
the setup process is complete.
All temporary configurations that are applied by Express
Setup, such as DHCP server, are removed.
Summary of Contents for ArmorStratix 5700 series
Page 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Page 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Page 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Page 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Page 547: ......