background image

Instructions

1336 REGEN-5.11     May, 1998

 

 

1336 REGEN
Converter Control Board 
Replacement — All Ratings

 

This publication will guide you through the replacement of the Converter 
Control Board for all 1336 REGEN Packages.

Each 1336R-MCB-SP1A kit consists of:

• (1) Converter Control Board (PN 74103-571-51)

• (1) Static Discharge Wrist Strap (PN 133256)

 

ATTENTION: 

 

This product and its associated equipment 

contains ESD (Electrostatic Discharge) sensitive parts and 
assemblies. Static control precautions are required when 
installing, testing, servicing or repairing this assembly. 
Component damage may result if ESD control procedures are 
not followed. If you are not familiar with static control 
procedures, reference publication 8000-4.5.2 "

 

Guarding Against 

Electrostatic Damage

 

" or any other applicable ESD protection 

handbook.

 

!

!

 

ATTENTION: 

 

Only personnel familiar with the 1336 REGEN 

Line Regen Package and associated equipment should plan or 
implement the installation, start-up and subsequent maintenance 
of the system. Failure to comply may result in personal injury 
and/or equipment damage.

 

ATTENTION: 

 

Electric Shock can cause injury or death. Remove 

all power before working on this product.

 

For all 1336 REGEN Line Regeneration Packages, a separate 120VAC 
user power supply is required.

Hazards of electrical shock exist if accidental contact is made with parts 
carrying bus voltage. Before proceeding with any installation or 
troubleshooting activity, allow at least one minute after input power has 
been removed for the bus circuit to discharge. Bus voltage should be 
verified by using a voltmeter to measure the voltage between the DC+ 
and DC– Converter Output Terminals.Do not attempt any servicing 
until bus voltage has diminished to zero volts.

 

!

 

DriveTools and DriveTools32 are trademarks of Rockwell International.

Reviews: