3-70
Programming and Parameters
PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
IN
PUT / OUTPUT
Digital
Outputs
581
[Dig Out Status]
Status of the standard digital outputs and relay outputs on the drive and on the
optional I/O Expansion circuit board (if present).
Read Only
629
[Relay Out 2 Sel]
Selects the source of the value that drives the N.O. relay
between the terminals 75 and 76.
Refer to “Option Definitions” on
Options:
Default:
5 =
“Ready”
1267
1268
1269
1270
1271
1272
1273
1274
[Inversion Out 1]
[Inversion Out 2]
[Inversion Out 3]
[Inversion Out 4]
[Inversion Out 5]
[Inversion Out 6]
[Inversion Out 7]
[Inversion Out 8]
Reverses the digital output signal.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
1275
[Inversion Relay2]
Inverts the signal for Relay Output 2.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
1392
[Relay Out 1 Sel]
Selects the source of the value that drives the N.O. relay
between the terminals 35 and 36.
Refer to “Option Definitions” on
Options:
Default:
25 =
“Contactor”
File
Gr
oup
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Related
Re
la
y O
ut2
Re
la
y O
ut1
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Di
gita
l Out8
Di
gita
l Out7
Di
gita
l Out6
Di
gita
l Out5
Di
gita
l Out4
Di
gita
l Out3
Di
gita
l Out2
Di
gita
l Out1
Default
0
0
x
x
x
x
x
x
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 =
“Not Used”
8 =
“Spd Limited”
16 = “Encoder Err”
24 = “ContactDB”
1 =
“Spd Zero Thr”
9 =
“Fault”
17 = “Diam Calc”
25 = “Contactor”
2 =
“Spd Thresh”
10 = “Power Loss”
18 = “Input1 Cmp”
26 = “Alarm”
3 =
“At Speed”
11 = “UserDefinedA”
19 = “Diam Reached”
27 = “Running”
4 =
“CurrentLimit”
12 = “UserDefinedB”
20 = “Speed Match”
28 = “Jogging”
5 =
“Ready”
13 = “Stop Control”
21 = “Accelerating”
29 = “Active”
6 =
“Ramp Pos”
14 = “Field Loss”
22 = “Decelerating”
7 =
“Ramp Neg”
15 = “Spd Fbk Loss”
23 = “Brake Cmd”
A
A
0 =
“Not Used”
8 =
“Spd Limited”
16 = “Encoder Err”
24 = “ContactDB”
1 =
“Spd Zero Thr”
9 =
“Fault”
17 = “Diam Calc”
25 = “Contactor”
2 =
“Spd Thresh”
10 = “Power Loss”
18 = “Input1 Cmp”
26 = “Alarm”
3 =
“At Speed”
11 = “UserDefinedA”
19 = “Diam Reached”
27 = “Running”
4 =
“CurrentLimit”
12 = “UserDefinedB”
20 = “Speed Match”
28 = “Jogging”
5 =
“Ready”
13 = “Stop Control”
21 = “Accelerating”
29 = “Active”
6 =
“Ramp Pos”
14 = “Field Loss”
22 = “Decelerating”
7 =
“Ramp Neg”
15 = “Spd Fbk Loss”
23 = “Brake Cmd”