Programming and Parameters
3-73
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
511 FVC2
Mode
Config
Configures Field Oriented Control - 2 (FOC2) operation.
Notes: Bit changes were made for firmware version 2.03. This parameter was changed to non-linkable for firmware version 3.01.
512
PMag Mode Config
Configures Permanent Magnet (PM) operation.
•
Bit 9 “ReflWaveComp” when set, Reflected Wave Correction is enabled.
Notes: Bit changes were made for firmware version 2.03. This parameter was changed to non-linkable for firmware version 3.01. Added bit 9 for firmware version
4.001.
513
V/Hz Mode Config
Configures V/Hz control mode operation.
Notes: This parameter was added for firmware version 2.03. Changed bit 3 from “Reserved” to “FastFluxDsbl” for firmware version 3.03. Bits 8, 9, and 21 were
changed to be not changeable while the drive is running.
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
!
ATTENTION: Do not modify this parameter.
Motor/Drive instabilities and damage could result.
Options
Ln
fS
ns
r Di
r
Ln
fS
ns
r Us
e
Re
se
rv
ed
F
lx
R
atRf Us
e
NT
C
Ac
tiv
e
Re
se
rv
ed
Re
se
rv
ed
CE
M
F
W
e U
se
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
B
usGain Comp
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Default
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
!
ATTENTION: Do not modify this parameter.
Motor/Drive instabilities and damage could result.
Options
Linr
Sns
r Dir
Linr
Sns
r Use
Re
ser
ved
Flx
R
at
Rf Use
Re
ser
ved
Re
ser
ved
Re
ser
ved
CEMF
W
e Us
e
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
PMVltRegUs
e
PMVltRegEn
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
flW
av
eComp
Bu
sGain Comp
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Re
ser
ved
Default
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
!
ATTENTION: Do not modify this parameter.
Motor/Drive instabilities and damage could result.
Options
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Vlt
M
inor
LpEn
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
ReflW
av
eComp
BusGain Comp
Reser
ved
Reser
ved
Reser
ved
Reser
ved
F
ast
Fl
ux
D
sb
l
Reser
ved
Reser
ved
Reser
ved
Default
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
1
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True