Specifications and Site Requirements
Electrical Specifications
74
MagneMotion
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
Table 4-14: NC-12 Node Controller Connections, 700-1482-00
Label
Description
Connector Type
CONSOLE
External terminal
DE-9, Male
ETHERNET
Ethernet – 10/100/1000 BaseTx
(auto-MDIX, auto-negotiation)
RJ45, Female, IP67
*
*
IP67 rated mating connector is not required.
DIGITAL I/O
Digital I/O, optically isolated, 16
input bits and 16 output bits, see
Spring-cage clamp
RS-232
RS-232 external communications
DE-9, Male
RS-422
RS-422 motor communications
M8 Nano-Mizer, 4-Pin, Male
†
†
MagneMotion recommends that the odd number connectors be used for upstream connections and the even
number connectors be used for downstream connections.
POWER
22–30 VDC, 20 W
DC Power Jack, 2.0 mm Coax, Male
Ground
M6 threaded stud
‡
‡
MagneMotion requires grounding the NC-12 through the ground stud with a minimum of 14 AWG wire.
Table 4-15: NC-12 Node Controller Connections, 700-1573-00
Label
Description
Connector Type
CONSOLE
External terminal
DE-9, Male
ETH
Ethernet – 10/100/1000 BaseTx
(auto-MDIX, auto-negotiation)
M12, Eurofast, 4-Pin, Female
DIGITAL I/O
Digital I/O, optically isolated, 16
input bits and 16 output bits, see
Spring-cage clamp
RS-232
RS-232 external communications
DE-9, Male
RS-422
RS-422 motor communications
M8 Nano-Mizer, 4-Pin, Male
*
*
MagneMotion recommends that the odd number connectors be used for upstream connections and the even
number connectors be used for downstream connections.
LVDC
22–30 VDC, 20 W
M12 Eurofast, 4-Pin, Male
Ground
M6 threaded stud
†
†
MagneMotion requires grounding the NC-12 through the ground stud with a minimum of 14 AWG wire.
Table 4-16: NC-12 Node Controller Indicators
Label
Description
Indicator Type
PWR/LVDC
ON – Indicates that DC power is on.
Green light