Accumulated percentage of motor overload. Continuously operating the motor over
100% of the motor overload setting will increase this value to 100% and cause a drive
fault.
Amount of time before a Drive Overload fault occurs if the load condition remains
constant. A value of 99999 means that the drive is operating under the overload level.
Captures and displays the output speed of the drive at the time of the last fault.
Captures and displays motor amps at the time of the last fault.
220
Motor OL Count
Range:
0.0 to 100.0% [1.0%]
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
See also:
47, 48
221
Mtr OL Trip Time
Range:
0.0 to 99999 [1]
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
See also:
220
224
Fault Speed
Range:
0.0 to +Maximum Freq [0.1 Hz]
0.0 to +Maximum Speed [0.1 RPM]
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
See also:
79, 225-230
225
Fault Amps
Range:
0.0 to Rated Amps x 2 [0.1 Amps]
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
See also:
224-230