Parameter Descriptions
3-61
Displays the source of the speed reference of the drive.
Displays the inputs currently preventing the drive from starting.
213
Speed Ref Source
Range:
0 = PI Output
1 = Analog In 1
2 = Analog In 2
3-6 = Reserved
7 = Pulse In
8 = Encoder
9 = MOP Level
10 = Jog Speed
11 = Preset Spd 1
12 = Preset Spd 2
13 = Preset Spd 3
14 = Preset Spd 4
15 = Preset Spd 5
16 = Preset Spd 6
17 = Preset Spd 7
18 = Local HIM
19 = DPI Port 2
20 = DPI Port 3
21 = DPI Port 4
22 = Network
23 = Reserved
24 = Auto Tune
25 = Jog Speed 2
26 = Scale Block 1
27 = Scale Block 2
28 = Scale Block 3
29 = Scale Block 4
30 = Pos/Spd Ref
31 = Position Reg
32 = Micro Pos
33 = Homing
34 = Decel Switch
35 = End Switch
36 = Unipolar Lim
37 = Rev Dis Lim
38 = Max Spd Lim
39 = Min Spd Lim
40 = Rev Spd Lim
41 = Load Trq Lim
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
See also:
90, 93, 96, 101
214
Start Inhibits
Range:
See figure 3.17
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
See also: