3-124
DBT Reach Drive User Manual
Displays the calculated total gear ratio as follows:
[(Gearbox Sheave) x (Gearbox Ratio)]/[Motor Sheave]
Calculates the negative torque maximum available from the dynamic brake resistor.
Sets the gearbox torque limit. This value is used in determining the Pos Torque Limit
(436) and Neg Torque Limit (437).
Selects the type voltage.
0 = 1 Phase:
Operates single phase loads connected to the U and V phases. Not
designed to operate single phase motors.
1 = 3 Phase:
Operates three phase loads.
646
Total Gear Ratio
Range:
0.00 to 32000.00 [0.01]
Default:
Read Only
Access:
2
Path:
Applications>Oil Well Pump
See also:
647
DB Resistor
Range:
0.0 to 100.0 Ohms [0.1]
Default:
10.4
Access:
2
Path:
Applications>Oil Well Pump
See also:
648
Gearbox Limit
Range:
0.0 to 200.0% [0.1%]
Default:
100.0 %
Access:
2
Path:
Applications>Oil Well Pump
See also:
650
Adj Volt Phase
Range:
0 = 1 Phase
1 = 3 Phase
Default:
1 = 3 Phase
Access:
2
Path:
Applications>Adjust Voltage
See also: