Publication

  1738-IN015C-EN-E - February 2010

Environment and Enclosure 

ATTENTION

This equipment is intended for use in overvoltage Category II 
applications (as defined in IEC publication 60664-1), at altitudes 
up to 2000 meters without derating.
This equipment is considered Group 1, Class A industrial 
equipment according to IEC/CISPR Publication 11. Without 
appropriate precautions, there may be potential difficulties 
ensuring electromagnetic compatibility in other environments 
due to conducted as well as radiated disturbance.
This equipment is supplied as ‘enclosed’ equipment. It should 
not require additional system enclosure when used in locations 
consistent with the enclosure type ratings stated in the 
Specifications section of this publication. Subsequent sections of 
this publication may contain additional information regarding 
specific enclosure type ratings, beyond what this product 
provides, that are required to comply with certain product safety 
certifications.
NOTE: See NEMA Standards publication 250 and IEC 
publication 60529, as applicable, for explanations of the degrees 
of protection provided by different types of enclosure. Also, see 
the appropriate sections in this publication, as well as the 
Allen-Bradley publication 1770-4.1 (Industrial Automation 
Wiring and Grounding Guidelines), for additional installation 
requirements pertaining to this equipment.

Summary of Contents for ArmorPoint 1738-APB

Page 1: ...PROFIBUS Adapter Series A Catalog Number 1738 APB Inside For See Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic Discharge 4 About the ArmorPoint PROFIBUS Adapter 4...

Page 2: ...well Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of informa...

Page 3: ...d not require additional system enclosure when used in locations consistent with the enclosure type ratings stated in the Specifications section of this publication Subsequent sections of this publica...

Page 4: ...l require an additional appropriate housing PROFIBUS connectors are sealed M12 micro style ATTENTION This equipment is sensitive to electrostatic discharge which can cause internal damage and affect n...

Page 5: ...cation Install the Module To install the module Mount the adapter and I O bases Wire the adapter 1738 APB Profibus Out Profibus In X10 X1 Adapter Status Profibus Status PointBus Status System Power Ad...

Page 6: ...the necessary holes for 8 M4 machine or self tapping screws 3 Mount the adapter using 8 M4 screws 4 Ground the system using the ground lug connection in the I O bases Note that the ground lug connecti...

Page 7: ...se a small blade screwdriver to rotate the switches Line up the small notch on the switch with the number setting you wish to use The two switches are most significant digit MSD and least significant...

Page 8: ...FIBUS Out Female 5 pin Micro M12 Reverse Keyway The recommended standard cordset for the PROFIBUS auxiliary connector is 889N F5AFC x where x equals 6 12 or 20 feet ATTENTION Make sure all connectors...

Page 9: ...ustration and the individual indicator troubleshooting tables Troubleshoot with the Indicators 1738 APB Profibus Out Profibus In X10 X1 Adapter Status Profibus Status PointBus Status System Power Adap...

Page 10: ...Hardware check is in progress Initialization is in progress Turn the adapter on or wait until the hardware check or initialization has finished Green Operating Normally The adapter is operating norma...

Page 11: ...eived Adapter has received a CLEAR command from the master None Red Initialization Error or No Module Error in PROFIBUS initialization No modules are installed in the backplane Perform initialization...

Page 12: ...check in progress Initialization in progress Turn the adapter on or wait until the hardware check or initialization has finished Green Operating Normally The adapter is operating normally None Flashi...

Page 13: ...ter Power indicator System Power Indicator State Status Description Recommended Action Off System Power Not Applied System power is not applied Apply power Green System Power Applied System power 5V i...

Page 14: ...current to an additional 1 3 A use a 1738 EP24DC Backplane Extension Power Supply Use multiple 1738 EP24DC modules to reach the maximum of 63 modules Cat No PointBus Current Requirements 1738 IB2M12...

Page 15: ...ons Inches 4 41 H x 2 83 W x 2 56 D LED Indicators 1 green red Adapter status 1 green red PROFIBUS status 1 green red PointBus status 1 green System Power PointBus 5V power 1 green Adapter Power 24V f...

Page 16: ...rature IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 20 60 C 4 140 F Storage Temperature IEC 60068 2 1 Test Ab Un package...

Page 17: ...00 4 6 10Vrms with 1 kHz sine wave 80 AM from 150 kHz 80 MHz Emissions CISPR 11 Group 1 Class A Enclosure Type Rating Meets IP65 66 67 when marked Certifications Certification Value Certifications 1 w...

Page 18: ...18 Publication 1738 IN015C EN E February 2010 Notes...

Page 19: ...19 Publication 1738 IN015C EN E February 2010 Notes...

Page 20: ...in the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your module up an...

Reviews: