  1738-IN015C-EN-E - February 2010

Field Power Bus

 

  Nominal Voltage

 

  Supply Voltage

 

  Supply Current

 

24V dc

 

10…28.8V dc range

 

10 A max

Field Side Power 
Requirements, Max

24V dc (+20% = 28.8V dc) @ 400 mA

Input Overvoltage Protection

Reverse polarity protected

Input Voltage Rating

24V dc nom

 

10…28.8V dc range

Isolation Voltage 

 

(Continuous-Voltage 
Withstand Rating)

50V rms

 

Tested at 1250V ac rms for 60 s

Inrush Current

6 A max for 10 ms

Interruption

Output voltage will stay within specifications when input 
drops out for 10 ms at 10V with max load

Dimensions Millimeters

112 H x 72 W x 65 D

Dimensions Inches

4.41 H x 2.83 W x 2.56 D

LED Indicators

1 green/red Adapter status

 

1 green/red PROFIBUS status 

 

1 green/red PointBus status

 

1 green System Power (PointBus 5V power)

 

1 green Adapter Power (24V from field supply)

Mounting Base 

 

Screw Torque

#8 screw, 7.5 lb-in. in aluminum 16 Ib-in. in steel

PointBus Output Current

1 A max @ 5V dc +5% (4.75…5.25)

Power Supply

Note that in order to comply with CE Low Voltage Directives 
(LVD), you must use either a NEC Class 2, a Safety Extra Low 
Voltage (SELV) or a Protected Extra Low Voltage (PELV) 
power supply to power this adapter. A SELV supply must not 
exceed 30V rms, 42.4V peak or 60V dc under normal 
conditions and under single fault conditions. A PELV supply 
has the same rating and is connected to protected earth.

ArmorPoint PROFIBUS Adapter - 1738-APB Specifications

Summary of Contents for ArmorPoint 1738-APB

Page 1: ...PROFIBUS Adapter Series A Catalog Number 1738 APB Inside For See Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic Discharge 4 About the ArmorPoint PROFIBUS Adapter 4...

Page 2: ...well Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of informa...

Page 3: ...d not require additional system enclosure when used in locations consistent with the enclosure type ratings stated in the Specifications section of this publication Subsequent sections of this publica...

Page 4: ...l require an additional appropriate housing PROFIBUS connectors are sealed M12 micro style ATTENTION This equipment is sensitive to electrostatic discharge which can cause internal damage and affect n...

Page 5: ...cation Install the Module To install the module Mount the adapter and I O bases Wire the adapter 1738 APB Profibus Out Profibus In X10 X1 Adapter Status Profibus Status PointBus Status System Power Ad...

Page 6: ...the necessary holes for 8 M4 machine or self tapping screws 3 Mount the adapter using 8 M4 screws 4 Ground the system using the ground lug connection in the I O bases Note that the ground lug connecti...

Page 7: ...se a small blade screwdriver to rotate the switches Line up the small notch on the switch with the number setting you wish to use The two switches are most significant digit MSD and least significant...

Page 8: ...FIBUS Out Female 5 pin Micro M12 Reverse Keyway The recommended standard cordset for the PROFIBUS auxiliary connector is 889N F5AFC x where x equals 6 12 or 20 feet ATTENTION Make sure all connectors...

Page 9: ...ustration and the individual indicator troubleshooting tables Troubleshoot with the Indicators 1738 APB Profibus Out Profibus In X10 X1 Adapter Status Profibus Status PointBus Status System Power Adap...

Page 10: ...Hardware check is in progress Initialization is in progress Turn the adapter on or wait until the hardware check or initialization has finished Green Operating Normally The adapter is operating norma...

Page 11: ...eived Adapter has received a CLEAR command from the master None Red Initialization Error or No Module Error in PROFIBUS initialization No modules are installed in the backplane Perform initialization...

Page 12: ...check in progress Initialization in progress Turn the adapter on or wait until the hardware check or initialization has finished Green Operating Normally The adapter is operating normally None Flashi...

Page 13: ...ter Power indicator System Power Indicator State Status Description Recommended Action Off System Power Not Applied System power is not applied Apply power Green System Power Applied System power 5V i...

Page 14: ...current to an additional 1 3 A use a 1738 EP24DC Backplane Extension Power Supply Use multiple 1738 EP24DC modules to reach the maximum of 63 modules Cat No PointBus Current Requirements 1738 IB2M12...

Page 15: ...ons Inches 4 41 H x 2 83 W x 2 56 D LED Indicators 1 green red Adapter status 1 green red PROFIBUS status 1 green red PointBus status 1 green System Power PointBus 5V power 1 green Adapter Power 24V f...

Page 16: ...rature IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 20 60 C 4 140 F Storage Temperature IEC 60068 2 1 Test Ab Un package...

Page 17: ...00 4 6 10Vrms with 1 kHz sine wave 80 AM from 150 kHz 80 MHz Emissions CISPR 11 Group 1 Class A Enclosure Type Rating Meets IP65 66 67 when marked Certifications Certification Value Certifications 1 w...

Page 18: ...18 Publication 1738 IN015C EN E February 2010 Notes...

Page 19: ...19 Publication 1738 IN015C EN E February 2010 Notes...

Page 20: ...in the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your module up an...

Reviews: