![Rockwell Automation Allen-Bradley PowerFlex SCR User Manual Download Page 52](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-powerflex-scr/allen-bradley-powerflex-scr_user-manual_1475768052.webp)
A-10
Specifications
PowerFlex SCR Bus Supply User Manual
Table A.D 690V, 50Hz Line Reactor Selection
Drives
Ranges of Drives DC Amp Sum for Typical Supply Transformers
(1)
Line Reactor
Sum of
DC Amps
630 kVA
5%
123
µ
H
800 kVA
5%
95
µ
H
1000 kVA
5.5%
86
µ
H
1250 kVA
6%
75
µ
H
1600 kVA
6%
59
µ
H
2500 kVA
6.5%
42
µ
H
3000 kVA
6.5%
33
µ
H
Induct.
[
µ
H]
Catalog No.
1321-
…
(2)
up to 203
—
130-150
130-157
130-162
130-170
140-180
150-185
2x150 3R160-B
(3)
130-175
151-190
158-203
163-203
171--203 181-203
186-203
230
3R160-C
176-203
191-203
—
—
—
—
—
150
3R160-B
75
3R160-A
204 to 255
—
—
—
—
—
204-210
204-220
2x110 3R200-B
(3)
204-206
204-230
204-245
204-255
204-255
211-255
221-255
185
3R200-C
207-255
231-255
246-255
—
—
—
—
110
3R200-B
55
3R200-A
256 to 319
—
—
—
—
—
—
256-260
2x90 3RB250-B
(3)
—
256-260
256-270
256-290
256-319
256-319
261-319
150
3RB250-C
256-280
261-319
271-319
291-319
—
—
—
90
3RB250-B
281-319
—
—
—
—
—
—
45
3RB250-A
320 to 407
—
—
—
—
320-360
320-407
320-407
125
3RB320-C
—
320-360
320-380
320-407
361-407
—
—
75
3RB320-B
320-407
361-407
381-407
—
—
—
—
40
3RB320-A
408 to 509
—
—
—
—
—
408-465
408-509
105
3RB400-C
—
—
408-414
408-450
408-509
466-509
—
60
3RB400-B
—
408-500
415-509
451-509
—
—
—
30
3RB400-A
510 to 635
—
—
—
—
—
510-520
510-580
85
3R500-C
—
—
—
510-538
510-570
521-635
581-635
50
3R500-B
—
—
510-540
539-635
571-635
—
—
25
3R500-A
636 to 763
—
—
—
—
—
—
636-650
65
3R600-C
—
—
—
—
—
636-763
651-763
40
3R600-B
—
—
—
—
661-763
—
—
20
3R600-A
764 to 938
—
—
—
—
—
—
764-780
48
3R750-C
—
—
—
—
—
764-850
781-938
29
3R750-B
—
—
—
—
—
851-938
—
15
3R750-A
939 to 1K0
—
—
—
—
—
—
—
42
3R850-C
—
—
—
—
—
939-1K0
939-1K0
27
3R850-B
—
—
—
—
—
—
—
15
3R850-A
(1)
The inductance value of the supply transformers includes 2.5 µH for 10 m feeder cable.
(2)
The number in the catalog string represents the fundamental AC current of the reactor.
(3)
Connect two reactors in series.
Summary of Contents for Allen-Bradley PowerFlex SCR
Page 1: ...PowerFlex SCR Bus Supply Firmware Version 1 xxx User Manual...
Page 4: ...soc ii Summary of Changes PowerFlex SCR Bus Supply User Manual Publication 20S UM001G EN P...
Page 6: ...ii Table of Contents PowerFlex SCR Bus Supply User Manual Publication 20S UM001G EN P...
Page 62: ...A 20 Specifications PowerFlex SCR Bus Supply User Manual Publication 20S UM001G EN P Notes...
Page 64: ...B 2 History of Changes PowerFlex SCR Bus Supply User Manual Publication 20S UM001G EN P Notes...
Page 67: ......