Supplemental Information
Appendix A
Logic Status Word for PowerFlex 700/700H/700S Drives
The AFE reference is the commanded bus voltage (for example, a value of 6000
represents 600.0V DC). The feedback value is the bus voltage measured in the
AFE.
Logic Bits
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Status
Description
x
Ready
0 = Not ready
1 = Ready
x
Active
0 = Not active
1 = Active
x
Motoring
0 = Not motoring
1 = Motoring
x
Regenerating
0 = Not regenerating
1 = Regenerating
x
In Precharge
0 = Not in precharge
1 = In precharge
x
Droop Active
0 = Not droop active for AFE
paralleling
1 = Droop active for AFE paralleling
x
Alarm
0 = No alarm
1 = Alarm
x
Faulted
0 = Not faulted
1 = Faulted
x
At Reference
0 = Not at reference
1 = At reference
x
Mot CurLim
0 = Not exceeding current limit in
Motoring Mode
1 = Exceeding current limit in
Motoring Mode
x
Regen CurLim
0 = Not exceeding current limit in
Regenerative Mode
1 = Exceeding current limit in
Regenerative Mode
x
Cmd Delayed
0 = Condition false
1 = Condition true
x
DCVoltRefID0
x
DCVoltRefID1
x
DCVoltRefID2
x
Reserved
Bits
Description
14
13
12
0
0
0
= DC Volt Ref
0
0
1
= Analog In 1
0
1
0
= Analog In 2
0
1
1
= DPI Port 1
1
0
0
= DPI Port 2
1
0
1
= DPI Port 3
1
1
0
= DPI Port 4
1
1
1
= DPI Port 5
Summary of Contents for Allen-Bradley PowerFlex 700AFE
Page 8: ...8 Rockwell Automation Publication 20Y UM001F EN P April 2017 Table of Contents Notes ...
Page 164: ...164 Rockwell Automation Publication 20Y UM001F EN P April 2017 Appendix B HIM Overview Notes ...
Page 184: ...184 Rockwell Automation Publication 20Y UM001F EN P April 2017 Index Notes ...
Page 185: ......