![Rockwell Automation Allen-Bradley PowerFlex 700AFE Hardware Service Manual Download Page 59](http://html.mh-extra.com/html/rockwell-automation/allen-bradley-powerflex-700afe/allen-bradley-powerflex-700afe_hardware-service-manual_1475495059.webp)
Rockwell Automation Publication 20Y-TG002C-EN-P - April 2017
59
AFE Power Structure Component Section
Chapter 4
See PowerFlex 700S and 700H Frame 10…14 Drives Maintenance
Stand Installation Instructions, publication
f. Slide the power structure outward onto the rails of the optional
Maintenance Stand.
Install the Power Structure in the Enclosure
Install the power structure in reverse order of removal. See the PowerFlex
Active Front End User Manual, publication
, for fastener torques
of AC supply, DC bus input, and ground connection terminations.
Remove the U, V, or W Phase Assembly from the Power Structure
To remove the U, V, or W phase assembly from the power structure, follow
these steps.
1. Remove the power structure from the AFE enclosure.
Remove the Power Structure from the Enclosure on page 54
2. Remove the ASIC Circuit board.
Remove the ASIC Circuit Board on page 50
.
ATTENTION:
The power structure is heavy. To avoid personal injury
or damage to the equipment, use caution when removing the power
structure from the enclosure.
IMPORTANT
Do not attempt to disassemble the power module within the U, V, or W
phase assembly.