![Rockwell Automation Allen-Bradley PowerFlex 7000 User Manual Download Page 413](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-powerflex-7000/allen-bradley-powerflex-7000_user-manual_1475431413.webp)
Rockwell Automation Publication 7000L-UM301F-EN-P - March 2020
413
Appendix
A
Catalog Number Explanation
a
Bulletin Number
Code
Description
7000A
“A” Frame (Air-cooled)
7000
“B” Frame (Air-cooled)
7000L
“C” Frame (Liquid-cooled)
b
Service Duty/Altitude Code
Code
Description
A
Normal Duty, 0...1000 m Altitude. Maximum 40 °C Ambient
B
Normal Duty, 1001...5000 m Altitude
Reduced Ambient (from 40 °C offering)
1001...2000 m = 37.5 °C
2001...3000 m = 35 °C
3001...4000 m = 32.5 °C
4001...5000 m = 30 °C
C
Heavy Duty, 0...1000 m Altitude. Maximum 40 °C Ambient
D
Heavy Duty, 1001...5000 m Altitude. Reduced Ambient
(from 40 °C offering) – same as “B” code above
E
Normal Duty, 0...1000 m Altitude. Maximum 35 °C Ambient
F
Normal Duty, 1001...5000 m Altitude
Reduced Ambient (from 35 °C offering)
1001...2000 m = 32.5 °C
2001...3000 m = 30 °C
3001...4000 m = 27.5 °C
4001...5000 m = 25 °C
G
Heavy Duty, 0...1000 m Altitude. Maximum 35 °C Ambient
J
Normal Duty, 0...1000 m Altitude. Maximum 50 °C Ambient
L
Heavy Duty, 0...1000 m Altitude. Maximum 50 °C Ambient
N
Normal Duty, 0...1000 m Altitude. Maximum 20 °C Ambient
Z
Custom Configuration (Contact Factory)
c
Drive Current Rating
(1)
(1) Not all amperages are available at all ambient/altitude configurations.
Code
Description
Code
Description
40
40 Amp
215
215 Amp
46
46 Amp
250
250 Amp
53
53 Amp
285
285 Amp
61
61 Amp
325
325 Amp
70
70 Amp
375
375 Amp
81
81 Amp
430
430 Amp
93
93 Amp
495
495 Amp
105
105 Amp
575
575 Amp
120
120 Amp
625
625 Amp
140
140 Amp
657
657 Amp
160
160 Amp
720
720 Amp
185
185 Amp
d
Enclosure Type
Code
Description
D
Type 1 w/gasket (IP21)
T
Type 1 w/gasket (IP21) – Seismic rated
K
Type 12 w/vents and filters (IP42)
U
Type 12 w/vents and filters (IP42) – Seismic rated
Position
1
2
3
4
5
6
7
7000L
A
40
D
A
RPDTD
1–...etc.
a
b
c
d
e
f