4-2
Troubleshooting
The condition or state of your drive is constantly monitored. Any
changes will be indicated through the LEDs and/or the HIM (if present).
Front Panel LED Indications
Figure 4.1 Typical Drive Status Indicators
Drive Status
➊
➋
Esc
7
8
9
4
5
6
1
2
3
.
0
+/-
Sel
Jog
Alt
POWER
STS
PORT
MOD
NET A
NET B
Exp
Param #
S.M.A.R.T.
Exit
Lang
Auto / Man
Remove
HOT surfaces can cause severe burns
CAUTION
➌
Esc
7
8
9
4
5
6
1
2
3
.
0
+/-
Sel
Jog
Alt
POWER
STS
PORT
MOD
NET A
NET B
Exp
Param #
S.M.A.R.T.
Exit
Lang
Auto / Man
Remove
HOT surfaces can cause severe burns
CAUTION
Frames
0 & 1
Frames
2 & 3
#
Name
Color
State
Description
➊
PWR
(Power)
Green
Steady
Illuminates when power is applied to the drive.
➋
STS
(Status)
Green
Flashing
Drive ready, but not running & no faults are present.
Steady
Drive running, no faults are present.
Yellow
See
page
Flashing,
Drive Stopped
A start inhibit condition exists, the drive cannot be
started. Check parameter 214 [Start Inhibits].
Flashing,
Drive Running
An intermittent type 1 alarm condition is occurring.
Check parameter 211 [Drive Alarm 1].
Steady,
Drive Running
A continuous type 1 alarm condition exists.
Check parameter 211 [Drive Alarm 1].
Red
See
page
Flashing
Fault has occurred. Check [Fault x Code] or Fault Queue.
Steady
A non-resettable fault has occurred.
➌
PORT
Green
–
Status of DPI port internal communications (if present).
MOD
Yellow
–
Status of communications module (when installed).
NET A
Red
–
Status of network (if connected).
NET B
Red
–
Status of secondary network (if connected).