Rockwell Automation Publication 520-UM001K-EN-E - August 2021
61
Chapter 2 Start Up
Viewing and Editing
Parameters
The following is an example of basic integral keypad and display functions.
This example provides basic navigation instructions and illustrates how to
program a parameter.
Step
Key
Example Display
1.
When power is applied, the last user-
selected Basic Display Group parameter
number is briefly displayed with flashing
characters. The display then defaults to
that parameter’s current value. (Example
shows the value of b001 [Output Freq] with
the drive stopped.)
2.
Press Esc to display the Basic Display
Group parameter number shown on power-
up. The parameter number will flash.
3. Press Esc to enter the parameter group
list. The parameter group letter will flash.
4.
Press the Up Arrow or Down Arrow to scroll
through the group list (b, P, t, C, L, d, A, f
and Gx).
5.
Press Enter or Sel to enter a group. The
right digit of the last viewed parameter in
that group will flash.
6. Press the Up Arrow or Down Arrow to scroll
through the parameter list.
7.
Press Enter to view the value of the
parameter.
Or
Press Esc to return to the parameter list.
8.
Press Enter or Sel to enter Program Mode
and edit the value. The right digit will flash
and the word Program on the LCD display
will light up.
9. Press the Up Arrow or Down Arrow to
change the parameter value.
10.
If desired, press Sel to move from digit to
digit or bit to bit. The digit or bit that you
can change will flash.
11.
Press Esc to cancel a change and exit
Program Mode.
Or
Press Enter to save a change and exit
Program Mode.
The digit will stop flashing and the word
Program on the LCD display will turn off.
12.
Press Esc to return to the parameter list.
Continue to press Esc to back out of the
programming menu.
If pressing Esc does not change the
display, then b001 [Output Freq] is
displayed. Press Enter or Sel to enter the
group list again.
HERTZ
FWD
Esc
FWD
Esc
FWD
or
FWD
Sel
or
FWD
or
FWD
VOLTS
FWD
Sel
or
PROGRAM
VOLTS
FWD
or
PROGRAM
VOLTS
FWD
Sel
PROGRAM
VOLTS
FWD
Esc
or
VOLTS
FWD
VOLTS
FWD
or
Esc
FWD
Summary of Contents for Allen-Bradley PowerFlex 520 Series
Page 8: ...8 Rockwell Automation Publication 520 UM001K EN E August 2021 Table of Contents Notes ...
Page 68: ...68 Rockwell Automation Publication 520 UM001K EN E August 2021 Chapter 2 Start Up Notes ...
Page 236: ...236 Rockwell Automation Publication 520 UM001K EN E August 2021 Appendix F PID Set Up Notes ...
Page 270: ...270 Rockwell Automation Publication 520 UM001K EN E August 2021 Index Notes ...