A522 [Freq 1 Ki]
Related Parameter(s):
A524 [Freq 2 Ki]
A526 [Freq 3 Ki]
PowerFlex 525 only.
Sets I-gain of “Vector” control mode when in frequency region 1, 2 or 3 for faster speed response during steady-state where motor is at its rated speed. If
[Speed Reg
Sel] is set to 1 “Manual”, these parameters can be changed.
Values
Default:
0.100 s
Min/Max:
0.000/10.000 s
Display:
0.001 s
PF 525
A527 [PM FWKn 1 Kp]
PowerFlex 525 only.
(With FRN 5.xxx and later.)
The gain to ensure good performance in field weakening region.
Values
Default:
350%
Min/Max:
0/2000%
Display:
1%
PF 525
A528 [PM FWKn 2 Kp]
PowerFlex 525 only.
(With FRN 5.xxx and later.)
The gain to ensure robustness under step load in weakening region.
Values
Default:
300%
Min/Max:
100/8000%
Display:
1%
PF 525
A529 [PM Control Cfg]
PowerFlex 525 only.
(With FRN 5.xxx and later.)
Control configuration for Feed Forward Decouple (FFD), Maximum Torque Per Amp (MTPA), and Load Disturbance Observer (LDOB).
Values
Default:
00111
Min/Max:
00000/00111
Display:
00000
PF 525
1 = Condition True, 0 = Condition False
FFD (Feed Forward Decouple)
Digit 1
MTPA (Maximum Torque Per Amp)
Digit 2
LDOB (Load Disturbance Observer)
Digit 3
Not Used
Not Used
Summary of Contents for Allen-Bradley PowerFlex 520 Series
Page 8: ...8 Rockwell Automation Publication 520 UM001K EN E August 2021 Table of Contents Notes ...
Page 68: ...68 Rockwell Automation Publication 520 UM001K EN E August 2021 Chapter 2 Start Up Notes ...
Page 236: ...236 Rockwell Automation Publication 520 UM001K EN E August 2021 Appendix F PID Set Up Notes ...
Page 270: ...270 Rockwell Automation Publication 520 UM001K EN E August 2021 Index Notes ...