Programming and Parameters
3-15
Advanced Program Group
(continued)
32 bit parameter.
A056 [Relay Out Level]
Sets the trip point for the digital output relay if the value of A055
is 6, 7 or 8.
Values
Default
0.0
Min/Max:
0.0/9999
Display:
0.1 – 1
32
A055 Setting
Min/Max
6
7
8
0/240 Hz
0/180%
0/815 Volts
A067 [Accel Time 2]
Sets the rate of acceleration for all speed increases except jog.
Values
Default
20.0 Secs
Min/Max:
0.0/600.0 Secs
Display:
0.1 Secs
Maximum Freq
Accel Time
Accel Rate
=
Speed
0
Time
[Maximum Freq]
[Accel Time]
[Decel Time]
0
Acceleration
De
ce
lerat
ion
A068 [Decel Time 2]
Sets the rate of deceleration for all speed decreases except jog.
Values
Default
20.0 Secs
Min/Max:
0.1/600.0 Secs
Display:
0.1 Secs
Maximum Freq
Decel Time
Decel Rate
=
Speed
0
Time
[Maximum Freq]
[Accel Time]
[Decel Time]
0
Acceleration
De
ce
lerat
ion
userman.book Page 15 Friday, June 21, 2002 2:48 PM
Summary of Contents for Allen-Bradley PowerFlex 4
Page 4: ...soc 2 userman book Page 2 Friday June 21 2002 2 48 PM ...
Page 6: ...ii userman book Page ii Friday June 21 2002 2 48 PM ...
Page 32: ...1 22 Installation Wiring Notes userman book Page 22 Friday June 21 2002 2 48 PM ...
Page 70: ...4 8 Troubleshooting Notes userman book Page 8 Friday June 21 2002 2 48 PM ...
Page 74: ...A 4 Supplemental Drive Information Notes userman book Page 4 Friday June 21 2002 2 48 PM ...
Page 82: ...B 8 Accessories and Dimensions Notes userman book Page 8 Friday June 21 2002 2 48 PM ...
Page 88: ...C 6 RS485 DSI Protocol Notes userman book Page 6 Friday June 21 2002 2 48 PM ...
Page 92: ...Index 4 Notes userman book Page 4 Friday June 21 2002 2 48 PM ...
Page 93: ...userman book Page 1 Friday June 21 2002 2 48 PM ...