Rockwell Automation Publication 20P-TD001K-EN-P - January 2021
51
PowerFlex DC Drive and Field Controller Technical Data
Field Controller Frames A and B AC Input Line Fuses
AC input line fuses are externally mounted for frame A and B drives and must be sourced separately.
PowerFlex DC Drive Frame A and B Field Circuit Fuses
Field circuit fuses are internally mounted and provided with the drive. See Fuse Code FS3 in PowerFlex DC Drives Frame A and B Fuse
Information on page
. Also, see PowerFlex DC Drive Frame A Field AC Input Line Fuses Location on page
B Field AC Input Line Fuses Location on page
for fuse locations.
575V AC Input Drives
Frame
Drive Current
Rating Code
DC Current [A]
AC Line Current
[A]
Bussmann
Mersen
North American FWP Type
North American A70P / A70QS Type
B
067
67.5
55.1
FWP-125A
A70QS125-4K
101
101.3
82.7
FWP-200A
A70QS200-4K
135
135
110.3
FWP-250A
A70QS250-4
270
270
220.6
FWP-600A
A70QS600-4K
405
405
330.9
FWP-800A
A70QS800-4
Cat. No.
Frame
Size
DC Amps AC Line Amps
Bussman
Mersen
Ferrule
FWP Type
North American FWP
Type
Ferrule
A70QS Type
North American
A70P / A70QS Type
23PFCx017
A
17
14
FWP-25A14F
FWP-25B
A70QS25-14F
A70P25-4
23PFCx060
60
49
FWP-80A22F
FWP-80B
A70QS80-22F
A70QS80-4
23PFCx120
120
98
—
FWP-150A
—
A70QS150-4K
23PFCx245
B
245
201
FWP-300A
A70QS300-4
23PFCx365
365
299
FWP-400A
A70QS400-4
23PFCx570
570
467
FWP-600A
A70QS600-4
230V AC Input Drives
Fr
am
e
Drive Current
Rating Code
Field Amps
Type
Quantity
Bussmann
Mersen
SIBA
A
7P0
10
6 x 32 mm
2
FWH-016A6F
E085449
70 125 40.16
9P0
012
020
029
038
055
073
14
093
110
B
146
20
10 x 38 mm
2
FWC-25A10F
A60Q25-2
60 033 05.25
180
218
265
360
434