94
Rockwell Automation Publication 20P-TG002B-EN-P - February 2018
Chapter 3
Part Replacement Procedures
• Use the following table to determine the proper tightening torque for
the bus bars connected to the SCR modules:
Bimetal Thermostats
Replacement
Remove the Bimetal Thermostats
Follow these steps to remove the bimetal thermostats.
1. Read the General Safety Precautions on page
2. Remove power from the drive (see page
3. Remove the screws and washers that secure the plastic shields to the
bottom of the drive and remove the shields.
4. Remove the bolts, washers and wiring from the U phase AC input
power terminal and the D power terminal.
230V AC Input
Drive Current
Rating Code
DC Amps
AC Line Amps
Hp
Final Torque
146
146
119
40
4.5…5.5 N
•
m (40…48.7 lb
•
in)
180
180
147
50
218
218
178
60
265
265
217
75
11…13 N
•
m (97.4…115 lb
•
in)
360
360
294
100
434
434
355
125
460V AC Input
Drive Current
Rating Code
DC Amps
AC Line Amps
Hp
Final Torque
167
167
136.4
100
4.5…5.5 N
•
m (40…48.7 lb
•
in)
207
207
169.1
125
250
250
204.3
150
11…13 N
•
m (97.4…115 lb
•
in)
330
330
269.6
200
412
412
336.6
250
3
3
U Phase
4
Bottom View of Drive
D Terminal