Rockwell Automation Publication 2711T-UM001E-EN-P - March 2019
63
Set Up the BIOS Settings and Desktop Icons
Chapter 5
12.
If FactoryTalk View ME Station was configured in
to automatically
start after any MobileView 2711T terminal startup or reboot, then the
application automatically starts after
.
If FactoryTalk was not configured to automatically start, then you must tap
the FactoryTalk View ME Station icon on the MobileView terminal-
desktop to load and run the application.
Right-click Touch Screen Functionality and FactoryTalk View ME Station
If your FactoryTalk View ME Station software uses momentary push buttons and
you require long press times to activate those buttons, then the right-click touch
screen functionality within the MobileView operating system must be disabled.
By default, right-click functionality is enabled for the touch screen.
To disable right-click touch screen functionality, perform the following steps.
1.
From the MobileView 2711T terminal desktop, tap Touch Configuration.
2.
On the Touch tab of the Pen and Touch dialog box, tap Press and hold.
With Press and hold highlighted, tap Settings.
IMPORTANT
EWF must be disabled before you change right-click functionality, and then
enabled afterwards. For more information, see
Summary of Contents for Allen-Bradley MobileView 2711T-VMBRACKET
Page 6: ...6 Rockwell Automation Publication 2711T UM001E EN P March 2019 Table of Contents Notes ...
Page 14: ...14 Rockwell Automation Publication 2711T UM001E EN P March 2019 Chapter 1 Features Notes ...
Page 100: ...100 Rockwell Automation Publication 2711T UM001E EN P March 2019 Index Notes ...
Page 101: ...Rockwell Automation Publication 2711T UM001E EN P March 2019 101 Index Notes ...
Page 102: ...102 Rockwell Automation Publication 2711T UM001E EN P March 2019 Index Notes ...
Page 103: ......