Parameter Descriptions
Chapter 9
The rectifier rated RMS input voltage is displayed as
x.x
V AC.
The rectifier rated RMS input current is displayed as
x.x
A.
The rectifier software version number is displayed as
x.xxx
.
The allowed level of imbalance in input voltage entered as
x.x
%.
An Input V Imbalance fault (fault 226) is generated if Line V Imbalance (23) is
greater than V Imbalance Lmt (60) for this amount of time.
27
Rated Volts
Range
0.0...6553.5 V AC [0.1V AC]
Default:
Read Only
Access:
0
Path:
Monitor > Drive Data
See also:
28
Rated Amps
Range:
0.0...6553.5 A [0.1 A]
Default:
Read Only
Access:
0
Path:
Monitor > Drive Data
See also:
29
Control SW Ver
Range:
x.xxx
Default:
Read Only
Access:
0
Path:
Monitor > Drive Data
See also:
60
V Imbalance Lmt
Range:
Path:
0.0 to 20.0% [0.1%]
Default:
10.0
Access:
0
Path:
Configuration > AC Line
See also:
23, 61
61
V Imbalance Time
Range:
1.0...10.0 seconds [0.1 seconds]
Default:
1.0
Access:
0
Path:
Configuration > AC Line
See also:
23, 60
Summary of Contents for Allen-Bradley LiquiFlo 2.0
Page 1: ...LiquiFlo 2 0 AC Drive User Manual OriginalInstructions ...
Page 6: ...6 Rockwell Automation Publication D2 3518 4 January 2020 Table of Contents Notes ...
Page 8: ...8 Rockwell Automation Publication D2 3518 4 January 2020 Preface Notes ...
Page 12: ...12 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 1 Introduction Notes ...
Page 34: ...34 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 2 About the Drive Notes ...
Page 68: ...68 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 8 Programming Basics Notes ...
Page 267: ......