![Rockwell Automation Allen-Bradley LiquiFlo 2.0 User Manual Download Page 100](http://html.mh-extra.com/html/rockwell-automation/allen-bradley-liquiflo-2-0/allen-bradley-liquiflo-2-0_user-manual_1475412100.webp)
100
Rockwell Automation Publication D2-3518-4 - January 2020
Chapter 9
Parameter Descriptions
• Is set to 1 to indicate when the PI output equals positive limit or negative
limit.
Present value of the PI reference signal.
Present value of the PI feedback signal.
Present value of the PI error signal.
Present value of the PI output signal.
The Accel Time parameters set the rate at which the drive ramps to its output
frequency after a start command or during an increase in command frequency
(speed change). The rate established is the result of the following equation:
(Maximum Speed ÷ Accel Time) = Accel Rate
135
PI Ref Meter
Range:
-/+100.00% [0.01%]
Default:
Read Only
Access:
1
Path:
Speed Command > Process PI
See also:
124...138
136
PI Fdback Meter
Range:
-/+100.00% [0.01%]
Default:
Read Only
Access:
1
Path:
Speed Command > Process PI
See also:
124...138
137
PI Error Meter
Range:
-/+100.00% [0.01%]
Default:
Read Only
Access:
1
Path:
Speed Command > Process PI
See also:
124...138
138
PI Output Meter
Range:
100.0 Hz [0.1 Hz]
Default:
Read Only
Access:
1
Path:
Speed Command > Process PI
See also:
124...138
140
141
Accel Time 1
Accel Time 2
Range:
0.1...100.0 [0.1 sec]
Default:
10.0
Access:
140 = 0
141 = 0
Path:
Dynamic Control > Ramp Rates
See also:
142, 143, 146, 361...366
Summary of Contents for Allen-Bradley LiquiFlo 2.0
Page 1: ...LiquiFlo 2 0 AC Drive User Manual OriginalInstructions ...
Page 6: ...6 Rockwell Automation Publication D2 3518 4 January 2020 Table of Contents Notes ...
Page 8: ...8 Rockwell Automation Publication D2 3518 4 January 2020 Preface Notes ...
Page 12: ...12 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 1 Introduction Notes ...
Page 34: ...34 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 2 About the Drive Notes ...
Page 68: ...68 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 8 Programming Basics Notes ...
Page 267: ......