Publication 2094-UM001A-EN-P — September 2006
Connecting the Kinetix 6000 Drive System
95
Wiring the Motor Power (MP) Connector
This example applies to axis modules (AM) and the inverter section of
integrated axis modules (IAM).
Integrated Axis Module/Axis Module (MP connector)
Cable Shield Terminations
Factory supplied motor power cables for MP-Series, TL-Series,
1326AB, F-, and Y-Series motors are shielded, and the braided cable
shield must terminate at the drive during installation. A small portion
of the cable jacket must be removed to expose the shield braid. The
exposed area must be clamped (using the clamp provided) on top of
the IAM or AM and the power wires terminated in the motor power
(MP) connector plug.
Integrated Axis Module, Top
V
iew
(2094-BC02-M02-
S
is shown)
W
V
U
1 2 3 4
Cable
S
hield Clamp
SHOCK HAZARD
To avoid hazard of electrical shock, ensure shielded power
cables are grounded at a minimum of one point for safety.
IMPORTANT
For TL- and Y-Series motors, also connect the 152 mm (6.0 in.)
termination wire to the closest earth ground.
Refer to Pigtail Terminations on page 100 for more information.
Summary of Contents for Allen-Bradley Kinetix 6000
Page 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Page 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Page 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Page 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Page 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Page 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Page 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...