Fuse/Contactor Specifications
Make sure the selected components are properly coordinated and meet
acceptable codes including any requirements for branch circuit protection.
The following fuse examples are recommended for use with Kinetix 3 drives.
Table 3 - Fuse and Contactor Specifications
Drive Cat. No.
AC Input Power
(1)
(2)
(3)
Recommended Fuse
(1) Fuses specified are Bussmann fuses.
(2) FNQ-R fuses are described as time-delay fuses, Class CC.
(3) LPJ fuses are described as dual-element time-delay fuses, Class J.
Control Power
(4)
Recommended Fuse
(4) FRS-R fuses are described as dual-element time-delay fuses, Class RK5.
Contactor
(5)
(5) For contactors:
x
represents coil voltage,
y
represents the number of contacts.
2071-AP0
FNQ-R-7
FRS-R-2-1/2
FNQ-R-7-1/2
LPJ-6
100-K05xy
2071-AP1
2071-AP2
100-K09xy
2071-AP2
FNQ -R-10
100-K12xy
2071-AP8
FNQ-R-20
LPJ-20
100-C16
xy
2071-A10
2071- A15
FNQ-R-30
LPJ-30
100-C23
xy