50
Rockwell Automation Publication 2071-UM001E-EN-P - November 2013
Chapter 3
Kinetix 3 Drive Connector Data
Serial Interface Connection
The IEEE-1394 connectors (Comm0A and Comm0B) are provided on the
Kinetix 3 drive.
This table provides the drive’s default serial port configuration. This
configuration is used for communication between a drive and personal computer
with Connected Component Workbench software.
Table 22 - USB Communication Specification
This table provides the drive’s default serial port configuration. This
configuration is used for communication between a drive and personal computer
with Ultraware software.
Table 23 - RS-232
Serial Communication Specifications
Attribute
Value
Communication Protocol
RS-485
Baud
192,000
Data bits
8
Parity None
Stop bit
1
Operator interface bit pattern
1102
Cabling
Catalog numbers 2090-CCMUSDS with 1203-USB
Node address
248
Attribute
Value
Communication Protocol
RS-232
Baud
57,600
Data bits
8
Parity None
Stop bit
1
Operator interface bit pattern
0005
Cabling
Catalog number 2090-CCMPCDS
Summary of Contents for Allen-Bradley Kinetix 3 2071-A10