14
Rockwell Automation Publication 442G-UM002A-EN-P - December 2016
Chapter 1
General Description
Figure 9 - Escape Release Mounting Plate [mm (in.)]
Mounting Hardware Reference
Handle Assembly Mounting Plate is supplied with the following hardware:
4X DIN 7984-M6X12 ZN (screw)
4X DIN 433-6 NI (washer)
4X DIN 6797-JZ-D6,4 (lock washer)
Escape Release Mounting Plate is supplied with the following hardware:
4X DIN 7984-M6X8 (screw)
4X DIN 433-6 NI (washer)
4X DIN 6797-JZ-D6,4 (lock washer)
Typical Ethernet
Configurations
The Multifunctional Access Box with CIP Safety can be connected in any of
the following three network topologies: star, linear, or module level ring
(DLR).
10
(0.39)
32 (1.26)
3
(0.12)
6.5
(0.25)
12 (0.47)
17.5
(0.69)
17.5
135
(5.31)
113.5 (4.47)
4 (0.16)
170
(6.69)
20
(0.79)
89.4
(3.54)
M6 (4x)
20
(0.79)
68
(2.68)
43.5
(1.71)
83
(3.27)
7.5
(0.29)
86.5 (3.40)
19.5
(0.77)
ATTENTION:
The Multifunctional Access Box does not currently support time
sensitive applications based on CIP Sync™, including CIP Motion™
applications. Do not use the access box in DLR topologies where other nodes
are using CIP Sync or CIP Motion. To be used in linear topologies, where other
nodes are using CIP Sync or CIP Motion, the access box must be connected at
the end of the line.