2-10
Placing and Configuring the Drive
Table 2.E Mapping for User-Defined 2 Communication Format
For each of the communication formats, drive_module:O.LogicCommand
and drive_module:I.LogicStatus are provided as DINT data types. In
addition to these tags, the control bits for each are also available as Boolean
values with tag names that correspond to the control bits in the drive. This
gives you the option of programming the Logic Command and Status words
at the Boolean level or as an integer value.
Not all 32-bits within parameter 151 [Logic Command], are directly visible
in the PowerFlex 700S. To view all 32-bits, refer to parameter 152 [Applied
LogicCmd].
Controller Output Tag Element
Drive Parameter
Linked Parameter
LogicCommand
602 [FromDriveLogix00]
151 [Logic Command]
UserDefinedRealData[0]
603 [FromDriveLogix01]
User Defined
UserDefinedRealData[1]
604 [FromDriveLogix02]
User Defined
UserDefinedRealData[2]
605 [FromDriveLogix03]
User Defined
UserDefinedRealData[3]
606 [FromDriveLogix04]
User Defined
UserDefinedRealData[4]
607 [FromDriveLogix05]
User Defined
UserDefinedRealData[5]
608 [FromDriveLogix06]
User Defined
UserDefinedRealData[6]
609 [FromDriveLogix07]
User Defined
UserDefinedRealData[7]
610 [FromDriveLogix08]
User Defined
UserDefinedRealData[8]
611 [FromDriveLogix09]
User Defined
UserDefinedRealData[9]
612 [FromDriveLogix10]
User Defined
UserDefinedRealData[10]
613 [FromDriveLogix11]
User Defined
UserDefinedIntegerData[0]
614 [FromDriveLogix12]
User Defined
UserDefinedIntegerData[1]
615 [FromDriveLogix13]
User Defined
UserDefinedIntegerData[2]
616 [FromDriveLogix14]
User Defined
UserDefinedIntegerData[3]
617 [FromDriveLogix15]
User Defined
UserDefinedIntegerData[4]
618 [FromDriveLogix16]
User Defined
UserDefinedIntegerData[5]
619 [FromDriveLogix17]
User Defined
UserDefinedIntegerData[6]
620 [FromDriveLogix18]
User Defined
UserDefinedIntegerData[7]
621 [FromDriveLogix19]
User Defined
UserDefinedIntegerData[8]
622 [FromDriveLogix20]
User Defined
Controller Input Tag Element
Drive Parameter
Linked Parameter
LogicStatus
626 [To DriveLogix00]
155 [Logic Status]
UserDefinedRealData[0]
627 [To DriveLogix01]
User Defined
UserDefinedRealData[1]
628 [To DriveLogix02]
User Defined
UserDefinedRealData[2]
629 [To DriveLogix03]
User Defined
UserDefinedRealData[3]
630 [To DriveLogix04]
User Defined
UserDefinedRealData[4]
631 [To DriveLogix05]
User Defined
UserDefinedRealData[5]
632 [To DriveLogix06]
User Defined
UserDefinedRealData[6]
633 [To DriveLogix07]
User Defined
UserDefinedRealData[7]
634 [To DriveLogix08]
User Defined
UserDefinedRealData[8]
635 [To DriveLogix09]
User Defined
UserDefinedRealData[9]
636 [To DriveLogix10]
User Defined
UserDefinedIntegerData[0]
637 [To DriveLogix11]
User Defined
UserDefinedIntegerData[1]
638 [To DriveLogix12]
User Defined
UserDefinedIntegerData[2]
639 [To DriveLogix13]
User Defined
UserDefinedIntegerData[3]
640 [To DriveLogix14]
User Defined
UserDefinedIntegerData[4]
641 [To DriveLogix15]
User Defined
UserDefinedIntegerData[5]
642 [To DriveLogix16]
User Defined
UserDefinedIntegerData[6]
643 [To DriveLogix17]
User Defined
UserDefinedIntegerData[7]
644 [To DriveLogix18]
User Defined
UserDefinedIntegerData[8]
645 [To DriveLogix19]
User Defined
UserDefinedIntegerData[9]
646 [To DriveLogix20]
User Defined
Summary of Contents for Allen-Bradley DriveLogix 5730
Page 6: ...4 ...
Page 10: ...p 4 Notes ...
Page 22: ...1 12 What is DriveLogix5730 Notes ...
Page 68: ...3 20 Placing and Configuring Local I O Notes ...
Page 134: ...6 36 Communicating with Devices on an EtherNet IP Link Notes ...
Page 182: ...9 10 Communicating with Devices on a DH485 Link Notes ...
Page 200: ...B 10 Access Procedures Notes ...
Page 205: ......
Page 206: ......
Page 207: ......