background image

Installation and Operating Instructions

Bulletin 802K DIN 50041 IEC/Large Metal Body Standard Limit Switch

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Specifications

Installation of Allen-Bradley products should be in 
accordance with local and/or national codes. 
Servicing energized industrial control equipment can be 
hazardous if not in accordance to recommended safety 
procedures.

AC/DC Designation

A600; Q600

AC/DC Utilization Category

Alternating current: AC15 (50/60 Hz)
Ue (V): 120    240    500     600
le (A):     6         3       1.4      1.2
Direct current: DC13
Ue (V): 125    250    500    600
le (A):   0.55   0.27   0.13   0.1

Max. Fusing Rate

10 A fast acting

Impulse Voltage (Uimp)

2500V

Enclosure Protection

IP66

Pollution Degree

3

Storage/Operating 
Temperature

-25…+65 °C (-13…+149 °F)

Direct Opening Action

Normally closed only

Conductor Sizes

Use copper conductors only

Stranded

0.75…2.5 mm2 (0.02…0.09 in.2)
(18…14 AWG)

Solid

0.75…2.5 mm2 (0.02…0.09in.2)
(18…16 AWG)

IMPORTANT

Typical Wiring Diagrams

4 N.C.

41 31 21 11

42 32 22 12

2 N.O. 2 N.C.

43 33 21 11

44 34 22 12

Same polarity this side of block

1 N.O. 1 N.C.

11 23

12 24

Torque/Mounting

Rotating Operator Heads

When rotating operator heads, follow these steps:

1. Loosen the head mounting screws and remove the operating 

head from the switch enclosure.

2. Orient the operator head in one of the four positions offered. 

Make sure the loose parts are positioned correctly before 
affixing the operator head to the switch enclosure.

3. Tighten the four screws per the recommended torque 

specifications above.

Location

Torque

Heads

1.2 N•m (0.86 lb•ft)

Covers

1.6 N•m (1.18 lb•ft)

M5 Mounting

2.5…3.0 N•m (1.84…3.21 lb•ft)

Wire Clamp

0.9…1.0 N•m (0.66…0.74 lb•ft)

Lever 
Clamp

M5 Hex Screw

1.8 N•m (1.33 lb•ft)

M3/M4 Hex Screw

1.5 N•m (1.11 lb•ft)

Adj. Lever Screw

1.0 N•m (0.74 lb•ft)

Conduit

1.0 N•m (0.74 lb•ft)

Internal operator head components can become dis-
lodged when removing operator heads. Use caution 
during removal and assembly.

Check for switch operation with a continuity indicator 
before placing product in service.

IMPORTANT

IMPORTANT

Reviews: