Secure the Cables
All cables should be secured to each other or a fixed object after leaving the monitor by using the
supplied cable ties. Securing the cables provides strain relief and avoids loose, hanging cables. It is
particularly important in shock and vibration environments to reduce movement of the cables.
Functional Ground Screw
The pre-installed functional ground screw is not required for safety or regulatory compliance.
However, if a supplemental ground is desired, use the functional ground screw in the I/O port
panel of the monitor (
).
If using the functional ground screw, connect the product to earth ground (
) by using a
1.5 mm
2
(16 AWG) or larger external wire. Use a ground wire with green insulation and a yellow
stripe for easy identification.
Ship or Transport Product
If you need to ship the product via common carrier or transport it to another location, you must
first uninstall the product and place it in its original packing material.
ATTENTION:
Do not ship or transport the product when it is installed in a machine, panel, or
rack. Doing so may cause damage to the product. You must uninstall the product and place in
its original packing material before shipping. Rockwell Automation is not responsible for
damage incurred to a product that is shipped or transported while installed in a machine,
panel, or rack.