150
Rockwell Automation Publication 48CR-UM001A-EN-P - November 2019
Chapter 7
Parameter Overview
Diagnostics
The Diagnostics display/tab shows commands that allow you to change various
service messages and the name of the reader.
Counts (Read-only)
Figure 118 - WebConnect
(1)
Power-on
Uses a 16-bit counter that increments each time that the code reader is powered-
on.
Resets
Uses a 16-bit counter that increments each time that the code reader is reset. This
value is reset at power-on.
Power-on Saves
Uses a 16-bit counter that increments each time that a code reader setting is saved
for power-on.
Custom Default Saves
Uses a 16-bit counter that increments each time that a code reader custom default
is saved.
AOP View
WebConnect View
(1) The Counts parameter is available in WebConnect view only.
• Default: —
• Options: 16-bit counter (0 … 65,535)
• Default: —
• Options: 16-bit counter (0 … 65,535)
• Default: —
• Options: 16-bit counter (0 … 65,535)
• Default: —
• Options: 16-bit counter (0 … 65,535)