Parameter Overview
Chapter 7
– Standard
In Standard mode, the STATUS LED indicates the read cycle status
and the GOOD READ LED illuminates upon a good read at the end
of a read cycle. In a read rate test, these LEDs represent the percentage
of good reads per images captured.
– AIM Grade
When the LED mode is set to AIM grade, this parameter determines
which AIM grade to output via the LEDs. Using the read rate scale as
reference, if the AIM grade result was a grade A, all LEDs from
20…100% illuminate, if the result was a grade F, only the 20% LED
would illuminate.
ISO/IEC 16022 Grade
Provides visual grading of specific ISO/IEC 16022 parameters. Determines
which ISO/IEC 16022 parameter the code reader grades via the LEDs.
Calibration Options
This command specifies the operation of the calibration feature. The default
configuration performs calibration on gain and symbol type. The calibration
process optimizes the gain setting for the configured exposure.
Figure 91 - WebConnect
(1)
• Default: Final Grade
• Options: 0 = Final Grade
1 = Symbol Contrast
2 = Print Growth
3 = Axial Non-Uniformity
4 = Unused ECC
(1) The Calibration Options parameter is available in WebConnect view only.