Rockwell Automation Publication 1734-UM013J-EN-P - July 2014
103
Configure the Module in a GuardLogix Controller System
Chapter 5
b. Use the default values for Timeout Multiplier (2) and Network Delay
Multiplier (200).
A connection status tag exists for every connection.
If the RPI and connection reaction time limit for the network are set
appropriately, then this status tag should always remain low. Monitor all
connection status bits to verify that they are not going high
intermittently due to timeouts.
For more information about the Advanced Connection Reaction Time
Limit Configuration dialog box, refer to the GuardLogix Controllers
User Manual, publication
, the GuardLogix 5570
Controllers User Manual, publication
, or Compact
GuardLogix Controllers User Manual, publication
.
Configuration Ownership
The connection between the owner and the POINT Guard I/O module is based
on the following:
•
POINT Guard I/O module number
•
POINT Guard I/O safety network number
•
GuardLogix slot number
•
GuardLogix safety network number
•
Path from the GuardLogix controller to the POINT Guard I/O module
•
Configuration signature
If any differences are detected, the connection between the GuardLogix
controller and the POINT Guard I/O module is lost, and the yellow yield icon
appears in the controller project tree. For more information, see
IMPORTANT
Analyze each safety channel to determine what is appropriate. The default
Timeout Multiplier of 2 and Network Delay Multiplier of 200 creates a
worst-case input connection-reaction time limit of 4 times the RPI, and an
output connection-reaction time limit of 3 times the RPI. Changes to these
parameters should be approved only after a thorough review by a safety
administrator.
Summary of Contents for Allen-Bradley 1734-IB8S
Page 1: ...POINT Guard I O Safety Modules Catalog Numbers 1734 IB8S 1734 OB8S 1734 IE4S User Manual ...
Page 4: ...4 Rockwell Automation Publication 1734 UM013J EN P July 2014 Summary of Changes Notes ...
Page 10: ...10 Rockwell Automation Publication 1734 UM013J EN P July 2014 Table of Contents ...
Page 14: ...14 Rockwell Automation Publication 1734 UM013J EN P July 2014 Preface Notes ...
Page 186: ...186 Rockwell Automation Publication 1734 UM013J EN P July 2014 Appendix D Safety Data Notes ...
Page 211: ......