Appendix A Specifications
Inputs Receiver Plug-in,
Cascading Plug-in, and
Universal Plug-in
Response time
450L-B
• OSSD – ON to OFF
• Finger resolution <25 ms
• Hand resolution < 15 ms (for details see
• 450L-E
• OSSD – ON to OFF (no blanking, muting, beam coding, or cascading functionality
configured)
• Finger resolution <20 ms
• Hand resolution <13 ms (for detail see
450L PAC
• OSSD - ON to OFF (no muting, beam coding, or cascading functionality configured)
• <20 ms (for detail see
Power up time, max
5 s
OSSD restart time after clearance of
the protective field if automatic reset
)
Power Supply
24V DC ±15%; NEC Class 2 (U.S.). PELV per IEC 60204-1.
Power consumption (single stick)
450L-B Protective height:
• 150 mm (5.91 in.): 64 mA maximum
• 1950 mm (76.77 in.): 214 mA
(outputs not loaded)
450L-E Protective height:
• 150 mm (5.91 in.): 70 mA maximum
• 1950 mm (76.77 in.): 221 mA
(Output not loaded
450L-APC-IO-8: additional 40 mA (with termination plug)
450L-PAC number of beams:
• 1: 70 mA
• 2: 108 mA
• 3: 133 mA
• 4: 145 mA
(outputs not loaded)
450L-APC-IO-8: additional 40 mA (with termination plug)
Peak current during power-up cycle
800 mA maximum (outputs not loaded)
Duration of peak current during
power-up cycle
100 ms
Power down time (OSSD<2V)
3000 ms
Transmitted infrared wave length
Infrared (wave length 855 nm)
Aperture angle
Within ±2.5° @ 3 m (9.8 ft)
Synchronization
Optical
DIP switch selectable functions
Depends on inserted plug-in:
• 450L-B: start mode; external device monitoring (EDM); maximum operating range
• 450L-E: start mode; external device monitoring (EDM); maximum operating range,
beam coding, interference rejection, blanking, muting
• 450L PAC: start mode; external device monitoring (EDM); maximum operating range,
beam coding, muting
Lifetime expectancy
• DIP switch on plug-in: 1000 cycles
• Plug-in on transceiver stick: 50 cycles
Ambient light
• Incandescent lamp: 3000 lux or less
• Sunlight: 100,000 lux or less
(1)
450L PAC is based on 450L-E 30 mm hardware.
Table 73 - Operating Characteristics (Continued)
Attribute
Value
Table 74 - Inputs Receiver Plug-in, Cascading Plug-in, and Universal Plug-in
Attribute
Value
Input Manual start
Minimum duration 50 ms; maximum duration 5 seconds
Voltage level for Logic Low/0: 0…5V DC
Voltage level for Logic Hi/1: > 16V DC
Current: 7 mA typical
Input EDM
300 ms after activation of OSSD
Voltage level for Logic Low/0: 0…5V DC
Voltage level for Logic Hi/1: > 16V DC
Current: 7 mA typical
Input muting sensors
Voltage level for Logic Low/0:0…5V DC
Voltage level for Logic Hi/1:>16V DC
Current: 7 mA typical