Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
151
Chapter 9 Connected Components Workbench Software
Figure 146 - Reduced Resolution Settings
Reduced Resolution Blanking Rules
shows the rules for reduced resolution blanking. The
Connected Components Workbench software enforces these blanking rules
automatically. Since the transceiver sticks are synchronized with either the
first or last lens, only one end of the stick can be blocked (not both ends).
Table 68 - Reduced Resolution Settings
Setting
Description
Blanking type
Select Reduced Resolution.
Minimum lens number This setting is the first lens that participates in the range of lenses.
Maximum lens
number
This setting is the last lens that participates in the range of lenses.
Object monitoring
Always disabled for reduced resolution.
Number of objects
Select single or multiple objects.
Single - The height of the single object must be less than the maximum object size.
Multiple – The sum of the heights of all objects must be less than the maximum object size.
Maximum object size
Select the maximum height of the object or objects. The height is subject to certain rules
(see
).
Other zones
Select normal operation, reduced resolution one object, or reduced resolution two objects.