Installation/Wiring
1-19
Table 1.E Frame 2 - 6 Jumper Removal
(1)
(1)
Important: Do Not remove jumpers if the distribution system is grounded.
Frames Jumper Component
Jumper Location
No.
2-4
PEA
Common Mode Capacitors Jumpers are located above the Power Terminal
Block (see
➊
PEB
MOV’s
➋
5
Wire
Common Mode Capacitors Remove the I/O Cassette as described on
. The green/yellow jumper is located
on the back of chassis (see
for loca-
tion). Disconnect, insulate and secure the wire
to guard against unintentional contact with
chassis or components.
➌
MOV’s
Note location of the two green/yellow jumper
wires next to the Power Terminal Block (
). Disconnect, insulate and secure the wires
to guard against unintentional contact with
chassis or components.
➍
Input Filter Capacitors
6
Wire
Common Mode Capacitors Remove the wire guard from the Power Terminal
Block. Disconnect the three green/yellow wires
from the two “PE” terminals shown in
. Insulate/secure the wires to guard against
unintentional contact with chassis or compo-
nents.
MOV’s
Input Filter Capacitors
Summary of Contents for 9VT201-007HTNNN
Page 1: ...VTAC 9 AC Drive Firmware Version 3 xx User Manual ...
Page 4: ...soc 2 ...
Page 14: ...P 8 Overview Publication 9VT UM001D EN P Notes ...
Page 56: ...1 42 Installation Wiring Publication 9VT UM001D EN P Notes ...
Page 62: ...2 6 Start Up Publication 9VT UM001D EN P Notes ...
Page 130: ...3 68 Programming and Parameters Publication 9VT UM001D EN P Notes ...
Page 150: ...4 20 Troubleshooting Publication 9VT UM001D EN P Notes ...
Page 176: ...A 26 Supplemental Drive Information Publication 9VT UM001D EN P Notes ...
Page 196: ...B 20 Using the LCD OIM Publication 9VT UM001D EN P Notes ...
Page 212: ...C 16 Application Notes Publication 9VT UM001D EN P Notes ...
Page 223: ......