Maintenance
Preventive Maintenance
284
MagneMotion
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
Cable Connection Inspection
1.
Stop all motion on the sections of the QSHT transport system to be inspected.
2.
Verify that all cable connectors are fully seated and screws/locks are secured to
achieve good continuity.
3.
Inspect all cables for restricting bend radii, excessive tension, or physical damage.
4.
Return the QSHT transport system to normal operation.
Hardware Inspection
1.
Stop all motion on the sections of the QSHT transport system to be inspected.
2.
Turn off all QSHT transport system components with accessible power controls.
3.
Make sure that all motor stand hardware is secure.
4.
Make sure that all motor mounting hardware is secure.
5.
Make sure that all guideway mounting hardware is secure.
6.
Make sure that all vehicle grounding materials (for example, static brushes) are secure
and functioning properly.
7.
Make sure that all vehicle hardware, especially the hardware securing the magnet
array, is secure.
8.
Make sure that the Vehicle Gap (distance between the magnet array on the vehicle and
the motor) is within tolerance for all vehicles on all motors.
9.
Return the QSHT transport system to normal operation.
Transfer Log Files
Review the log files for each node controller and the HLC periodically to look for unexpected
messages.
Log files can be transferred from the node controller or SysLog server to a CD or external
USB device so they can be archived or e-mailed to ICT Customer Support, see the
Node Con-
troller Interface User Manual
.