3-2
LiquiFlo AC Power Modules, Hardware Reference Version 6.4
•
Do not install the drive above 1000 meters (3300 feet) without derating output
power. For every 91.4 meters (300 feet) above 1000 meters (3300 feet), derate the
output current 1%.
•
Verify that the drive location will meet the environmental conditions specified in table
3.1.
3.1.2 Determining Total Area Required Based on Drive Dimensions
Drive dimensions and weights are listed in table 3.2. Overall drive dimensions are
illustrated in figures 3.1, 3.2, and 3.3 as an aid in calculating the total area required by
the LiquiFlo drives.
Table 3.1 – Environmental Conditions
Condition
Specification
Operating Temperature (inside a NEMA cabinet)
0
°
C
to
+
55
°
C
1
(
32
°
to
131
°
F
)
1
With typical heat rise inside a cabinet, 40
°
C ambient outside usually results in 55
°
C inside.
Storage Temperature (Ambient)
-40
°
C
to
65
°
C
(−
40
°
to
149
°
F
)
Humidity
5% to 95% (non-condensing)
Table 3.2 – Drive Dimensions and Weights
LiquiFlo
Drive M/N
Frame
Dim. A
Dim. B
Dim. C
Dim. D
Dim. E
Dim. F
Dim. G
Weight
41L4060
41LR4060
B
475 mm
18.69”
800 mm
31.52”
357 mm
14.06”
397 mm
15.63”
711mm
28.00”
39 mm
1.53”
20 mm
0.79”
125 kg
275 lb
50LW4060
50LR4060
C
583 mm
22.96”
971 mm
38.23”
347 mm
13.66”
464 mm
18.25”
787 mm
31.00”
28 mm
1.09”
25 mm
1.00”
168 kg
370 lb
64LW4060
64LR4060
C
583 mm
22.96”
971 mm
38.23”
347 mm
13.66”
464 mm
18.25”
787 mm
31.00”
28 mm
1.09”
25 mm
1.00”
170 kg
375 lb
120L4060
D
1010 mm
39.75”
1245 mm
49.00”
360 mm
14.16”
838 mm
33.00”
1200 mm
47.25”
29 mm
1.12”
25 mm
1.00”
386 kg
850 lb
Summary of Contents for 41LR4060
Page 6: ...IV LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 8: ...VI LiquiFlo 2 0 AC Drive User Manual ...
Page 10: ...VIII LiquiFlo 2 0 AC Drive User Manual ...
Page 12: ...1 2 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 30: ...2 18 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 40: ...3 10 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 50: ...4 10 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 78: ...7 22 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 90: ...9 10 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 96: ...B 2 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 98: ...C 2 LiquiFlo 2 0 AC Drive User Manual ...
Page 100: ...D 2 LiquiFlo 2 0 AC Drive User Manual ...
Page 102: ...E 2 LiquiFlo 1 5 AC Power Modules Hardware Reference Version 1 2 ...
Page 107: ......