Publication 1734-UM001D-EN-P - April 2008
28
Install POINT I/O Modules
3.
Insert the module straight down into the mounting base and press to
secure, locking the module into place.
Install the Removable
Terminal Block
A removable terminal block is supplied with your mounting base assembly. To
remove, pull up on the removable terminal block (RTB) handle. This lets you
remove and replace the base as necessary without removing any of the wiring.
To reinsert the removable terminal block, proceed as follows.
1.
Insert the RTB end opposite the handle into the base unit.
This end has a curved section that engages with the mounting base.
2.
Rotate the terminal block into the mounting base until it locks itself in
place.
3.
If an I/O module is installed, snap the RTB handle into place on the
module.
24
VD
C
So
ur
ce
Ou
tpu
t
Mo
du
le
Sta
tus
Ne
tw
ork
Sta
tus
17
34
OB
4E
NO
DE
:
0
1
2
3
308802
WARNING
When you connect or disconnect the RTB with field-side power
applied, an electrical arc can occur. This could cause an
explosion in hazardous location installations. Be sure to remove
power or that the area is nonhazardous before proceeding.
30880
Summary of Contents for 1734-IA2
Page 4: ...Publication 1734 UM001D EN P April 2008 4 Summary of Changes Notes ...
Page 12: ...Publication 1734 UM001D EN P April 2008 12 Table of Contents Notes ...
Page 77: ...Publication 1734 UM001D EN P April 2008 Install POINT I O Modules 77 ...
Page 78: ...Publication 1734 UM001D EN P April 2008 78 Install POINT I O Modules ...
Page 179: ...Publication 1734 UM001D EN P April 2008 Default Data Maps 177 Notes ...
Page 180: ...Publication 1734 UM001D EN P April 2008 178 Default Data Maps ...
Page 236: ...Publication 1734 UM001D EN P April 2008 234 Notes ...
Page 241: ......