45
Element
Description
Spindle Stop active
Activate output for spindle stop signal (NO contact). The
output becomes active at the end of a cycle or on abort.
Spindle Stop switch dura-
tion
Duration of the switching signal in milliseconds
ESTOP-FOLLOW active
Output following ESTOP input. Can be used to switch off
voltage after the drives have come to a standstill.
ESTOP-FOLLOW
delay
If an emergency stop signal has been detected at the Estop
input, a delay can be set in motion after which the ESTOP
output is switched. Time in milliseconds.
COOL-output active
Output for coolant pump, activated at cycle start.
COOL-output delay
Delay for starting a cycle. This time is waited after activa-
tion of the COOL output until a cycle is started. This en
-
sures that the coolant has arrived at the tool before the cut
starts.
SETUP OUTPUTS
Element
Description
I/O Information
Shows the state of the inputs and outputs
ELS 4 Firmware Version
Firmwareversion
SELFTEST RESULT
Shows the results of the system selftest
SETUP INFORMATION
FACTORY SETTINGS
The settings can be reset to factory settings by pressing the programming reset button on
the right of the housing for approx. 7 seconds while the controller is running. You will then be
asked whether the settings should be reset. With START you reset the settings, STOP cancels
the process.
programming button/reset button