CAUTION
Only connect original accessories that are suitable for this control unit, otherwise the control
unit could be damaged. The protocol and the bus system are not standardized! This is NOT
a VGA connector for monitors!
27
Grounding
The control is operated with 12V DC voltage. The input is protected against reverse
polarity and equipped with a self-resetting fuse which trips at 1.5A. The power
supply should be able to supply approx. 1 A current.
The 6.3mm round plug is suitable for plugs with 2.1 or 2.5mm pins.
The pin is the positive pole.
EXTENSION CONNECTOR
Signals for an external control unit are output via a SUB-D-15-HD
socket. The signals are used to control a 16-bit I/O expander that
is addressed via a specially adapted 3.3V I2C bus. The assignment
is suitable for the offered ELS expansion modules.
GROUNDING
A 6.3mm flat plug is available for grounding the housing. The earthing should
always be connected to ensure good interference immunity of the controller.
POWER SUPPLY
SCREWTERMINAL DATA
The screw terminals are pluggable and can accept cables with the following cross-sections:
Solid (rigid)
0.14 mm² - 1.5 mm² AWG 28-16
Flexible
0.14 mm² - 1.5 mm² AWG 28-16
Flexible with wire end sleeve 0.25 mm² - 1.0 mm²
Stripping length:
7.0 mm
Maximum current:
8A
Screw thread:
M2
Tightening torque:
0.25 Nm