Setup of the drivers
Common to all motor drivers is the possibility to set them to the necessary parameters. Please
refer to the documentation of the system, there you will find the settings. They are also printed
on many drivers. As a rule, the following settings are necessary:
1.
Motor current
- The maximum current output to the motor must be set; if it is set too high,
there is a risk of the motor overheating; if it is set too low, the motor will not supply sufficient
torque.
2.
Steps per revolution
- Set the number of steps per revolution of the motor on the driver.
This setting must then also be entered in the control settings.
3.
Current reduction
- It is often possible to set whether the holding current should be re-
duced to generate less heat when the drive is at rest. This should be activated.
Please refer to the documentation of the manufacturers of the com-
ponents. All components purchased from Rocketronics are accom-
panied by corresponding documentation and pin assignments!
20
EMERGENCY-STOP
The complete machine must have an emergency stop device in which the ELS control must
also be integrated. The ELS has inputs and outputs for this purpose. An automatic restart
after the emergency stop has been triggered must be safely prevented!
An emergency stop of category 1 - controlled shutdown while maintaining the power supply
- is required to carry out the shutdown. The energy supply is only to be interrupted after the
machine has come to a standstill.
This procedure brings the spindle and drives to a standstill as quickly as possible. Only then
can the power supply be interrupted..
Please refer to the EMERGENCY STOP description in the Digital Inputs chapter.